  1. S

    New T-15 salt at 5,800

    well.... wouldn't you get an error message if the unit didn't like that high a level ? if the system doesn't object, whats the downside except a little bit of a salt taste ? it will eventually sort itself out , right ?
  2. S

    no chlorine with auto pilot

    no but measured it and its ok. and not sure what measuring it at the cell tells me... if its correct there then it should be correct in the pool . if the pool is zero and there are no bubbles then that's already that answer...
  3. S

    no chlorine with auto pilot

    90 degrees. i'm in the carribean and it never gets below 85 ... even at night
  4. S

    no chlorine with auto pilot

    hi installed total control system 2 or 3 mos ago and all was perfect. had to do some minor touch up to perimeter tile so drained the pool about 1/2 way. system continued to run for the 3 or 4 days it took me to do the work. refilled pool and , obviously , got low salt warning...
  5. S

    galvanic corrosion

    its a superior product and i have used it often. impervious to everything. completely and absolutely waterproofs the surface and fill cracks if they exist, expands and contacts with any reasonable expansion or flex, lasts , essentially forever and is avaialable in any color. it has a draw...
  6. S

    galvanic corrosion

    there never was a question about that. but those bits of wire are , if correctly placed , are 2.5 inches below the surface of the concrete, then 1/4 " of plaster, then 3 coasts of epoxy. and if i screwed up and didn't see some poking thru ( and i hand inpsected the surface before the...
  7. S

    galvanic corrosion

    i can try but there is really nothing to see. it/they are simple tiny brown dots against a blue backround on a flat wall in about 8 places on about a 100 ft perimeter or so. i can take a piece of 600 and scuff it away and it leaves a tiny brown dot about .020 in diameter that is the...
  8. S

    galvanic corrosion

    i understand the theory and the concept... but in the absence of any measureable voltage at any level betwen any two of anything, where is the current flow coming from ? and what are you suggesting as far as hooking a positve lead to the pool ? ... that sounds insane to me.
  9. S

    galvanic corrosion

    well... new is new. i am an engineer and built the pool with my crew. the concrete set for 90 days before it was finish pastered and then it got 3 coats of epoxy after nuetralizing the concrete. no holes, no metal, no drillings. the first spots showed up in 2 weeks, the others in about...
  10. S

    galvanic corrosion

    ok... i'l bite... how do you test for " stray voltage " or is that one of those unicorn/ufo myth things that takes the blame when ever everything else fails...
  11. S

    galvanic corrosion

    have no access to the rebar anymore and i have had meters between everything and evereything and find 1/10 th volt dc every once in a while but thats all. does grounding or bonding the actual concrete do anything ?
  12. S

    galvanic corrosion

    new 16,000 gal concrete pool with epoxy coating using autopilot total control. water chemistry is good and all levels acceptable. have developed a few tiny rust spots coming thru the the epoxy. very very small ... a 1/16 " dia sort of thing. also the stainless pool lights have developed...
  13. S

    AutoPilot Digital... help please

    in the intiall install menu there are a series of system settings . in one of them you tell the device what cell is in it. if you have replaced a 48 with a 42 and didn't tell your system that then its still looking for the various values generated by the 48 and is likely the source of your...
  14. S

    autopilot total control install completed

    good morning troops, a few months ago i inquired here about which swg to buy and after all the research ended up with the autopilot total control. installation is done and its been up and running for a month or so with acceptable results . if anyone is...
  15. S

    what calculation and what salt...

    i have seen that thread and discussed this in depth with jason last year while making the decision on which way to go. you do bring up an interesting point however.... i am in the carribean so the water tems are tradionally high... 60 and 70's in the winter 80's and high 90's in the...
  16. S

    what calculation and what salt...

    thx for taking the time to answer... i hate to screw things up by being stupid. at first blush, morton annoys me by not declaring their purity level... and second there are bad reviews for the morton regarding clogging and ruined sensors... now the first may just me being picky but i worry...
  17. S

    what calculation and what salt...

    good morning troops... since the last visit i have purchased and getting ready to install a " total control " saltwater system... i have two relatively simple questions.... 1) several of their calculations ask for " average depth " and then they ask for...
  18. S

    AutoPilot's Total Control System Review

    well... i have mine here ready to install. there is more work to be done so it won't be for another 30 days or so but we'll see then. did you do your own installation ?
  19. S

    AutoPilot's Total Control System Review

    so your ph automation works as advertised ?
  20. S

    best generator

    yes. i understand that concept completely and am going to great pains to ensure compatibility. that is a lesson long learned and thank you.
  21. S

    AutoPilot's Total Control System Review

    hello jason, this is the system i am looking at buying. the last post here was two years ago give or take... have they resolved any of the issues and is their tech support any better these days ? steve
  22. S

    best generator

    thats wonderful information, all of you, and thanks. let me do some reading and research now and ill be back. thanks again.
  23. S

    best generator

    good morning, it is my intention to spend a fair bit of time reading all the back posts here but if i may , a first question.... i have a pool being finished up that will be , roughly 15,000 gallons. i think i want to use a salt generator system for the chlorine as...