Search results

  1. VA2AZ

    Return water leaving SWG after filter pump shuts down

    Hey, I do not need this forum often, but when I do I get great response. Had a pool heater installed in December, which included a check valve between heater and SWG. For whatever reason, hoping to get some suggestions, after the filter pump stops, the water in the salt cell slowly goes down...
  2. VA2AZ

    Filter blew it's top off

    Fortunately I was in my backyard when this happened. Heard a pop, then noticed a geyser coming out of my pool equipment area. I had 4-5" of water around the enclosure before I could hit the circuit breakers. The top closure dome with pressure guage of the 24" Hayward sand filter had blown off. I...
  3. VA2AZ

    Heat Pump thoughts for PHX inground

    Last Nov, I had my 4' to 7' deep, 12'x24' plaster pool renovated to a 3.8' deep x 12'x24' pebblesheen pool. Approx gals went from 12.2k to 8.4k. right now pool is coming alive with winter temp of 49 leaving for 67 and rising every day. Running Nat Gas to equipment area is cost prohibitive, so I...
  4. VA2AZ

    Pump Run Times - Checking the Pulse

    Recently had Filter pump 1 hp motor replaced with a 2 speed 1hp motor. I have been adjusting the speeds and think I have it the way I need it and the way it will help lower the electric bill. Attached file is what I have set the run times for (summer ATT) and for the winter when temps drop. I...
  5. VA2AZ

    Filter Motor replacement

    The motor, after 13 years, decided to throw sparks and let the smoke out. Home warranty is replacing motor with 2 speed motor. What control is recommended to go from high speed to half speed? Thanks ahead!
  6. VA2AZ

    Booster pump for cleaning system making noise

    I have separate 1hp pumps for filter and cleaning/love seat jets. The cleaning motor is starting to make noise. Not bad for a 11+ yr old whisperflo! AZ law is a little confusing, but it looks like I have to replace, when it lets the smoke out, with a 2 speed pump. I have a PCC2000 infloor...
  7. VA2AZ

    Rebuilt Pool motors - PHX area

    I want to lower my elec usage and replace a 1hp whisperflo (circa 2002) motor with a 1/2frhp two speed whisperflo motor. Has anyone had any experience or knowledge about www.azpoolmotors.com? Thanks in advance. Milt
  8. VA2AZ

    Potassium Water softener used for filling pool

    I have a water softener for my house, and it supplies all outlets, except the irrigation system. It is softened with potassium chloride vs sodium chloride(personal age and health reasons). It is used to provide the proper level in the pool, as well as supplementing after a backwash. Does this...
  9. VA2AZ

    Chemical levels - Too much information?

    First time pool owner of just over a year (purchased a house with a 10 year old pool). I have been managing/monitoring my pool for a year now and it seems like I am missing something (or am I). My "pool-guy" tells me about my chlorine and PH levels (once a week), and I add Chlorine (increase SWG...
  10. VA2AZ

    IG Returns - two challenges

    I have a Paddock IG pool, 12.5k gal, has five returns. Two on deep end, one each side and one by steps in shallow end. The return right in front of the drain basket is not returning. The eyeball and lock ring are off to make sure it was not the eyeball. Nothing is coming out. ?? The return by...