Search results

  1. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    Just to followup in case someone finds this later through Google, it wasn't the cell. I purchased a new APUREM controller, and a new PLC1400 cell and installed them both. Both of my existing cells worked fine with the new APUREM controller, so it was definitely something on the boards. As I...
  2. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    This is the troubleshooting guide I'm using it's for an older system, but it's very simliar. https://images.inyopools.com/cloud/documents/jandy-aqua-pure-error-codes.pdf There's a flow-chart to diagnose problems, and all the test points, etc are clearly listed in terms of what the numbers...
  3. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    Yes, I get 123 with one back board, and 124 with the other back board. It doesn't matter which cell I use, the errors report back the same. So... Back board A with Cell 1 - 123 Back board B with Cell 1 - 124 Back board A with Cell 2 - 123 Back board B with Cell 2 - 124 And yes, those are...
  4. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    Yes, it does have an LCD - it's a 17 year old system at this point, but it still uses the same Jandy 1400 cell. Just an older setup on the boards themselves. Jandy Chlormatic III
  5. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    Yes, the salt level is correct. It's reading the same on the temp/flow/salinity sensor as the reading I got when I took the water to have it tested at the local pool store. As far as the front-board, there simply aren't any available. I thought that might be the problem too, so I send it out to...
  6. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    These are generic cells, each with their cable hard wired into the cell - it's not a bad cable. There have been two different cables used as they're directly attached to the cell. Also, I'm not using the jumper wire between the backboard, and the cell - the cell is directly plugged into the...
  7. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    I've tried two different cells, both brand new. Unless I got two bad cells from the factory, that doesn't seem like it should be the problem.
  8. R

    Jandy Aquapure/Chrlormatic - Help with these board readings?

    I'm running into all kinds of issues trying to fix my SWG, and yes, I know it's old. It's the Jandy Aquapure/Chlormatic with the two boards, a front, and a back board. I've tested all the points on the back board, and got the following readings. 1-8 - 77.6 VAC ( manual says 75 ) 2-7 - 66.5...