    Intelli-ph Pump Motor Direction

    It’s just amazing how lame some of these billion dollar companies can be. I sent an email on this to someone at Pentair and all he could say was that he no longer works in customer service rather than alert his team of a potential problem. He told me to contact customer service. I told him that...
  2. jprince924

    Intelli-ph Pump Motor Direction

    It’s actually easier to pull the blue cover off and flip the white squeeze tube which reverses the pink in and out acid hoses and reinstall the blue cover. I don’t think the white squeeze tube cares which it’s being squeezed. Overthinking? Absolutely 😝😂😆, but who cares? I’m retired and having...
  3. jprince924

    Intelli-ph Pump Motor Direction

    New pump. Notice the in and out. It is reversed.
  4. 1687487133305.jpeg

    1687487133305.jpeg

  5. jprince924

    Intelli-ph Pump Motor Direction

    Original pump. Notice the in and out
  6. 1687486648760.jpeg

    1687486648760.jpeg

  7. jprince924

    Intelli-ph Pump Motor Direction

    You are absolutely correct and apparently when Pentair constructed your system it was with a board that had the correct polarity. I’m using the original board but I upgraded to the new pump. Obviously when Pentair started selling complete units with the newer blue pump they reversed the polarity...
  8. jprince924

    Intelli-ph Pump Motor Direction

    That is a Stenner. Mine spins in the opposite direction of the arrows on the pump face. If I don’t reverse the tubes or motor polarity, it will pump into the tank instead of pumping into the pool water. Is yours correct? Maybe me is not correct.
  9. jprince924

    Intelli-ph Pump Motor Direction

    I used to have the square shur-flo pump where the motor spun in the same direction as the arrows. I have upgraded to the new blue stenner pump where the motor spins in the opposite direction of the arrows. This is where there is a problem. In order to get the acid into the pool, you either have...
  10. jprince924

    Stenner Pump not Pumping

    You are going to love this!! try looking at the rotation that the pump is turning. It should be rotating towards the pump outlet. If not, it is pumping air back into the acid tank instead of pulling acid from the tank. I had this problem when I upgraded from the shur-flo to the stenner. the pump...
  11. jprince924

    Intelli-ph Pump Motor Direction

    The new blue stenner pump head has arrows indicating a counter-clockwise spin but the motor only spins clockwise. The older shur-flo pump has the arrows spinning in the clockwise direction so if you upgrade the shur-flo to newer stenner using the stenners arrow flow you will not be feeding acid...