Search results

  1. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Gents, I am in the Baltimore area, and if you want to work on this setup and party, I will finance it! Maybe bring in a band! :P Thank you all for your help, I apprecaite it, I will keep you posted on how things go!
  2. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Response from Raypak "Looks like the unit is suffering from low flow conditions (not gas pressure as I first indicated) and the water chemistry reports we've received indicate aggressive water chemistry conditions. There is quite a bit of corrosion present on the UG bypass as well." Nice thing...
  3. IMG_0767.JPG

    IMG_0767.JPG

  4. IMG_0768.JPG

    IMG_0768.JPG

  5. IMG_0769.JPG

    IMG_0769.JPG

  6. IMG_0770.JPG

    IMG_0770.JPG

  7. IMG_0772.JPG

    IMG_0772.JPG

  8. IMG_0771.JPG

    IMG_0771.JPG

  9. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Hi again, thank you for the help and advice. Waiting to hear what the MSP from Raypak says when thry come out to check the unit re" gas pressure. Please understand I am a total novice to this! As far as equipment, I posted in another reply pictures, although I am sure they are not detailed for...
  10. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Lastly, should this one be toast and the warranty company does not replace it, any reccomendations for a replacement?
  11. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    The pool is a Salt Pool, so to boost chlorination (instead of using the skimmers), I presume there should be something on the pool return post heater?
  12. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Hey James, thanks for the reply and to everyone who has taken an interest, I apprecaite it. Here are the pictures that I was delivered by the service tech...
  13. Resized_Resized_20230601_141013.jpeg

    Resized_Resized_20230601_141013.jpeg

  14. Resized_Resized_20230601_141020.jpeg

    Resized_Resized_20230601_141020.jpeg

  15. Resized_Resized_20230601_140702.jpeg

    Resized_Resized_20230601_140702.jpeg

  16. Resized_Resized_20230601_140726.jpeg

    Resized_Resized_20230601_140726.jpeg

  17. Resized_Resized_20230601_140113.jpeg

    Resized_Resized_20230601_140113.jpeg

  18. Resized_Resized_20230601_140120.jpeg

    Resized_Resized_20230601_140120.jpeg

  19. Resized_Resized_20230601_135515.jpeg

    Resized_Resized_20230601_135515.jpeg

  20. Resized_Resized_20230601_140051.jpeg

    Resized_Resized_20230601_140051.jpeg

  21. Resized_Resized_20230601_135349.jpeg

    Resized_Resized_20230601_135349.jpeg

  22. Resized_Resized_20230601_135352.jpeg

    Resized_Resized_20230601_135352.jpeg

  23. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    So next steps, do I ask them to test the regulator? Is that a testable item?
  24. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    At this point, I think the manifold is toast. I will have the pool company check the pressure of that.
  25. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Natural gas, I will have to look up the models…
  26. schoeps

    Heater destroyed in 1 month? So confused! [pics]

    Hi all, thank you so much for the replies, I really apprecaite it. IS the regulator inside the unit or is it that disc thing on the outside in picture 4? Thank you again, I really apprecaite your help!
  27. 1.jpg

    1.jpg

  28. 2.jpg

    2.jpg

  29. 3.jpg

    3.jpg

  30. 4.jpg

    4.jpg