    Help "Configuring" Screenlogic2 for two pumps

    Hi Jim. No. It goes pump --> filter --> heater --> SWG --> pool jets. Unfortunately I do not think there is room to move the actuator to after the SWG. I was thinking about caming the actuator valve so that even after it switches to swimjet1 some water would still be going down the filter...
  2. E

    Help "Configuring" Screenlogic2 for two pumps

    @Jimrahbe Now the issue I am having is that when I hit swimjet1 it diverts all the water from heater/salt cell to swimjet1, however it keeps "Pool" running, which means the SWG and heater are still running but all water is being diverted away from heater/SWG. I guess I can make sure to turn the...
  3. E

    Help "Configuring" Screenlogic2 for two pumps

    I think I got it! The pump on it's display had a Max RPM set below the 3450, so when the control panel tried to set it to 3450 it would just turn the pump off. You figure there would be a popup warning or something for this! I feel like I'm using 1995 software, lol. Thanks for your help AGAIN :)
  4. E

    Help "Configuring" Screenlogic2 for two pumps

    Hi @Jimrahbe. Yes Pump1 is assigned to Pool Address 1 and Pump2 assigned to Pool Address 2. Still haven't been able to figure it out. I deleted all the schedules to try and trouble shoot. Essentially if I take the Filter/Pool pump (Pump1) and hit "swimjets1" it moves the actuator valve...
  5. E

    Help "Configuring" Screenlogic2 for two pumps

    Hi Jim Do both of your IntelliFlo pumps get constant AC power?? yes Do both pump's display "Display not Active" when in AUTO? yes Thanks for you help
  6. E

    Help "Configuring" Screenlogic2 for two pumps

    Thank you @Jimrahbe , you are always so helpful. No other automated valves (except for Intellilevel, but I think I am just going to not hook this up because I've heard it has a lot of trouble? I am also already using Valve A and Valve B on the comm board, not sure where or how I would hook the...
  7. E

    Help "Configuring" Screenlogic2 for two pumps

    Hi all, I honestly couldn't figure some of these things without all your help, so thank you in advance. I wanted to see if someone could help me essentially configure the settings on Screenlogic2 for my Easytouch 8. I have downloaded the "Screenlogic Configurator" on my PC and am using that...
  8. E

    Pentair Easytouch 8/Intelliflo/Intellichlor Electrical issues (breaker keeps tripping and salt cell not getting power)

    Hi Jim. This solved it! I had the SWG hooked up for 120v. When I switched to 240v it worked. Thanks for your help Sir
  9. IMG_7360.jpeg

    IMG_7360.jpeg

  10. E

    Pentair Easytouch 8/Intelliflo/Intellichlor Electrical issues (breaker keeps tripping and salt cell not getting power)

    I attached some photos. I know they’re not the best ones. Thanks for your help Jim
  11. IMG_7347.jpeg

    IMG_7347.jpeg

  12. IMG_7348.jpeg

    IMG_7348.jpeg

  13. IMG_7353.jpeg

    IMG_7353.jpeg

  14. IMG_7356.jpeg

    IMG_7356.jpeg

  15. IMG_7357.jpeg

    IMG_7357.jpeg

  16. IMG_7358.jpeg

    IMG_7358.jpeg

  17. IMG_7359.jpeg

    IMG_7359.jpeg

  18. IMG_7358.jpeg

    IMG_7358.jpeg

  19. E

    Pentair Easytouch 8/Intelliflo/Intellichlor Electrical issues (breaker keeps tripping and salt cell not getting power)

    Hi there, Thanks in advance for your help. I don't know what I would do without this community! I have done all the electrical myself, so I may have made a mistake and hope someone can help me. I have all Pentair equipment. Pentair easytouch 8 (with integrated salt cell transformer) and...
  20. E

    Pentair Intellilevel wiring question

    Hey JamesW. Thanks so much for you help. That is all really helpful! Really do appreciate it. There is no cut cord in the EasyTouch (unfortunately). I think I just need to buy a 3 pin connector. I think this is the right one? Amazon.com Stupid question: it looks like when they connect the wires...
  21. E

    Pentair Intellilevel wiring question

    Hi, has anyone wired a pentair intellilevel automatic pool filler up before? I believe the prior pool builder cut the cord coming off the intellilevel to the control panel (easytouch 8 in my case). From the intellilevel manual it looks like it is suppose to be a three wire cord with a connector...
  22. intellilevel.jpg

    intellilevel.jpg

  23. intellilevel 2.jpg

    intellilevel 2.jpg

  24. E

    Pool Electrical question

    Thanks for the reply. The power to the pump is 240. It's Pentair VS pump (intelliflo) so it will be hot wired at the relay. The goal of doing 120V on the Salt cell is because I don't have space for a double pole circuit breaker. Thanks for your help :)
  25. E

    Pool Electrical question

    Hi there, Had a quick electrical question I was hoping someone could help me with. I have an easy touch 8 with integrated SCG transformer and board in it. I am trying to figure out how to connect the transformer for 120V (rather than 240v). Please see attached imagine. From the wiring diagram...
  26. 1695934473866.png

    1695934473866.png

  27. Screenshot (59).png

    Screenshot (59).png

  28. E

    Pool Pump Electrical Question

    from the pool pumps to the pool subpanel (pentair easytouch)
  29. E

    Pool Pump Electrical Question

    Hi. I have two pentair intelliflo variable speed 3HP pumps 220v. I am going to use #10 THHN wire for each of them. Can they be run in the same conduit? Or the 220V #10 wire needs to each be run in its own conduit? Thanks! :)
  30. E

    Gunite/Shotcrete Question

    I have a permit to build by owner.