Search results

  1. C

    Replacing bearings on Speck pump - broken thru-bolt

    I have a Speck ES90 II pump with a single speed US Motors EZ48 KSSJXRME-2238 motor. I think the seal has failed, as the motor is quite rusted. I'm hoping to replace the bearings and the seals and give it a bit more life. One of the thru-bolts snapped off when I disassembled it, but I was able to...
  2. bearing.png

    bearing.png

  3. bearing.png

    bearing.png

  4. pump.png

    pump.png

  5. C

    Mounting new pump with a 2" 45 degree fitting?

    Hi, I'm planning to replace my existing single speed (1.0 THP Speck) with a 1.5 HP Intelliflo 3 VSF pump (I already bought the pump, I understand that a 3 HP might have been better). I need to get a pool installer out to take a look at installing it (I had Leslie's come out but that was a...
  6. IMG_6064.jpeg

    IMG_6064.jpeg

  7. New pump layout.png

    New pump layout.png

  8. IMG_6065.jpeg

    IMG_6065.jpeg

  9. IMG_6070.jpeg

    IMG_6070.jpeg

  10. C

    Controlling SWG with new Pentair Whisperflo VST

    Jim, I unfortunately had already ordered the new 1.5 HP pump. I figured I can run it at lower speed for more hours. Right now I run my 1.0 THP pump 8 hours a day at full speed (single speed pump). It is moving about 32 gpm. If I run the newer pump for 24 hrs, I assume I can run it at around...
  11. C

    Controlling SWG with new Pentair Whisperflo VST

    Jim, That is a great suggestion. I wasn't aware of that pump. It comes with integrated WiFi and the relay card, so I don't need any extra automation devices. I've ordered one from Leslie's. They didn't have the 011066 model that comes with the relay board, so I ordered the basic pump 011065...
  12. C

    Controlling SWG with new Pentair Whisperflo VST

    Right now my mechanical timer is inside the house, with just a single circuit running out to the pool that goes both to the pump and the SWCG. If I kept that setup, it would cut power to the Whisperflo as well. If there was some kind of relay output at the Whisperflo above a certain RPM (enough...
  13. C

    Controlling SWG with new Pentair Whisperflo VST

    I currently have a Speck ES90-II pump with a US Motors EZ48 motor with a THP:1.0. I have 1.5" PVC piping and the pressure gauge on my sand filter is showing around 15-17 psi at the moment. I have a ~15,000 gallon pool with one return by the stairs, one skimmer and one port about 16" down near...
  14. C

    Separate water bags for leaf net and solid cover?

    I bought a solid cover (tarp style) as well as a leaf net. I wanted to try the leaf net this year to see if it keeps the solid tarp cover cleaner. I was thinking that I could remove the leaf net occasionally to remove all the leaves. Both the tarp cover and leaf net have loops for water bags...
  15. Screenshot 2023-08-21 at 11.23.56.png

    Screenshot 2023-08-21 at 11.23.56.png

  16. C

    Robot spilling dirt when pulled out of water

    Hi, I have a Maytronics Dolphin Nautilus which is a few years old. It looks like the one in the picture below. I've noticed that when I lift the Dolphin out of the pool, that a bunch of sand and dirt is draining from it as i'm lifting it out. There is still plenty of sand/dirt caught by the...
  17. C

    Skimmer sinking

    I've noticed that my skimmer and the pavers around it are slowly sinking. The pavers used to be right underneath the coping, but now there is about a 1" gap. The top of the skimmer is now also tilted, it is lower near the pool. I'm fairly sure that I don't have a leak in my skimmer or the...
  18. skimmer - without collar.png

    skimmer - without collar.png

  19. skimmer - side view.png

    skimmer - side view.png

  20. skimmer-inside view.png

    skimmer-inside view.png

  21. C

    Pressure test poly pipe

    I want to pressure test my underground pool plumbing. I think my underground pipe is black poly pipe (see picture) . It doesn't look like flexible PVC. I assume the grey coupler has barbs going into the poly pipe, and since this is a 30+ year old pool, I probably shouldn't try to take the barbed...
  22. overview.png

    overview.png

  23. poly pipe.png

    poly pipe.png

  24. coupler 1.png

    coupler 1.png

  25. pressure tester.png

    pressure tester.png

  26. C

    Patching vinyl liner at top step of IG pool

    My pool had an ugly patch on top of a patch done by the previous homeowner. It didn't appear to leak last summer, but after opening the pool last weekend, I was losing 3/4" overnight. It appears that patches failed over the winter. It is a really tricky location to patch, because the tear is in...
  27. patch and rip location.png

    patch and rip location.png

  28. liner gap may 9.png

    liner gap may 9.png

  29. liner gap may 11.png

    liner gap may 11.png

  30. C

    Repairing a leaking vinyl liner patch

    I inherited a vinyl IG pool which has a patch on top of a patch. The top patch doesn't even have rounded corners. I've ordered a dye syringe to check, but given my water loss (I did a bucket test and saw about 3/8" more loss in the pool than in the bucket over 36 hours), I'm pretty sure the...