Search results

  1. D

    IntelliFlo VSF pump Alarm F90052

    J - Under normal circumstances the power to the pump is never really shut off so no alarms when the Chlorinator cycles - same with solar heater. This recent alarm was, I am pretty sure, the result of a power system problem. We are in Vero and since the latest hurricane FPL has been doing...
  2. D

    IntelliFlo VSF pump Alarm F90052

    I do not know (re: via filter relay load terminal). However, if I energize the main pump breaker, the pump is not powered on. The Chlorinator timer relay must be turned on for that to occur. The solar heating circuits are also energized at the same time. Sort of a cascade effect. might this...
  3. D

    IntelliFlo VSF pump Alarm F90052

    We have occasional power outages and/or voltage fluctuations and as this is a new installation we are at times confronted with "new, challenging learning opportunities". Enter a new one, "Alarm, Power Off - F90052" All keys locked, no reset... nothing. Reset main breaker, nothing except flow...