Search results

  1. G

    Trouble with my Hayward 250FDN throwing LO error code

    Okay, that's fair, as it will result in more pressure being available to the heater as a result.
  2. G

    Trouble with my Hayward 250FDN throwing LO error code

    Okay great, thanks @cptkirk, will pull the filters out after work today and give it a try. The elevation of the heater relative to the pool @JamesW is no more 2'-6". It has been running for about 6 years though so don't suspect this represents a challenge unless you had another perspective...
  3. G

    Trouble with my Hayward 250FDN throwing LO error code

    I will try pulling the filters out to see if still throws the LO error code.
  4. G

    Trouble with my Hayward 250FDN throwing LO error code

    There seems to be a good flow going into the pool so it doesn't visually appear that the filter is causing a restriction.
  5. G

    Trouble with my Hayward 250FDN throwing LO error code

    I increase the speed up to about 2380 rpm to 2420 rpm. I haven't changed the filter cartridges for a while and there currently is a 10psi pressure showing on the gauge on the top of the filter.
  6. G

    Hello Everyone

    Thanks so much. I just posted one. :)
  7. G

    Trouble with my Hayward 250FDN throwing LO error code

    I own a Hayward 250FDN Pool Heater and it starts intermittently. When the heater is cold I increase the flow rate on my pump as it is variable speed drive so that the LO flow error code clears. Once the low flow (LO) error code clears I switch the main panel from Standby over to Pool heating...
  8. G

    Hello Everyone

    Am an owner of an Hayward 250FDN Pool Heater and having a few challenges with it.