Search results

  1. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    I tested my water last night and my FC levels were 15! I've reduced the SWG to 45% and will run it for a day or so and recheck. pH is coming up slowly so i picked up a utility pump and will make a fountain tonight. Water is a balmy 85*F today!
  2. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Flow switch has been verified as fully functional. I've tested it a couple times and it's worked flawlessly. That said i'm still good down to 500 RPM without an alarm! I'm currently running at 1100 RPM which works out to 150 watts. Not bad.
  3. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Regarding pump speed. I understand the generally accepted theory here is to run it at +100 rpms from the "No Flow" indication on the CircuPool controller. The thing is i got down to as low as 300 RPM and I still never received the now flow alert. Any thoughts? Also i ran my pump for 24 h...
  4. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Got it! I'll increase the FC by ~.5 tonight before shutting the pump down.
  5. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    FC was 3.5 on my TF-100 kit. Referencing the pool math app i'm .5 high but referencing the CYA/FC ratio it should be 4. Which way should i swing for optimal comfort? Thank you! I have a temporary solution in place now using a transfer pump and a hose attachment to spray the pool water back...
  6. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Current Test Results via TF-100: CL/BR: 5/10 pH: 6.8 FC: 3.5 CC: (Threw water away early accidentally) CH: 50 TA: 70 CYA: 60 Salt: 3400 Temp: 80.9*F Test at store: PH: 6.8 FC: 2.3 TC: 2.3 TA: 75 CH: 107 CYA: 64 Salt: 3500 Close but certainly a bit different. @ajw22 - I'm going to increase...
  7. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    The pool is full, pump is running and filter is filtering. Things are looking good. I ran a full TF-100 Test (well most of it) last night and here are my final results: pH - 7.2 CL/BR - 0 Chlorine - 0 (I did not run FC or CC tests due to no Chlorine) TA - 60 CH - Didnt run CYA - 0 Salt - 200...
  8. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    The pool install process has made significant progress over two full days. It was significantly more expensive than expected, but the problems were far greater than imagined. At one point i almost wondered if i should go in-ground with how much work they had put in. I found a fiberglass shell...
  9. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    The trench has been dug and we've completely relocated where it will be placed. It will now be just out of frame in the top right of the previous photo. I dug the hole and placed the post in cement tonight. My electrician is coming in the AM to wire everything up and run the conduit. I...
  10. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    I'm told the reason for the twist lock at the pool outside is because it's required by local code. I spoke with a neighbor who just had a pool installed this past winter and he confirmed. There also needs to be a 120v outlet near the pool as a convenience outlet per code. I agree it's odd...
  11. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    I've received everything with the exception of the surge protector and the actual pool. I expect to receive the surge protector tomorrow and a call from the pool shipper to schedule delivery for tuesday. The electrician is going to come tuesday and has offered to trench as well which is a...
  12. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Great, that saves a bunch on the CB cost. Solid, bare 8 gauge it is then. I believe Lowes has it by the foot or the electrician has this he said.
  13. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Install bullet #7) The pump should be permanently connected to either a circuit breaker, 2-pole timer or 2-pole relay. If AC power is supplied by a GFCI circuit breaker, use a dedicated circuit breaker that has no other electrical loads. Does this mean i shouldnt or cant wire it where the VSP...
  14. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    The building inspector said that using the CB in the basement, next to a window with direct line of sight would pass. I'll ask the electrician tomorrow and verify with the inspector to be sure i dont run afoul. Is powder Sodium Hypochlorite effictive as well? I've been seeing this while...
  15. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Timer/load center will be in the basement. Plugs, filter and pump will be >6 feet from the pool. Thank you for your help. In regards to chlorine. Should i be using Sodium Hypochlorite? Is there any reason to use Cal-Hypo? I plan to take a water sample to the pool store tomorrow to get...
  16. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    @ajw22 thank you for your help! I was able to get the pump, filter and SWG ordered today. I went with Sta-Rite SuperMax VSP 343001 Pentair RP 200 Canister CircuPool RJ45+ Intermatic PE25300 I have the electrician stopping by tomorrow at 730am to plan the electrical run. Next is getting...
  17. 20200601_181921.jpg

    20200601_181921.jpg

  18. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    I just got the PoolMath app and found the online calculator. Is there a recommended stabilizer brand? I'll calculate the numbers and start obtaining materials (salt, bleach, stabilizer, test kit) this week. I need to get the suggested test kit in the mail, which should happen this week and...
  19. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Got it. Thank you. Any thoughts on initial pool timer settings? Also, i hope you're ready for a real fun question. In the last half hour there has been plans made for me to travel the week that this pool is installed or shortly there after. Is there a guide or anything I can look at to...
  20. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    @ajw22 I owe you a beer or 10 for that. My word that was comprehensive and AMAZING! THANK YOU! If you ever find your self in the southern RI/CT area, let me know. I'm going to pick a pump tonight but i think the WFDS-4 is the best price/performance choice for me right now. I'll pair that...
  21. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    @ajw22 - Thank you for all of your advice. You've helped me a ton. I put in the order tonight for the pool and will work out the final details with the filter tomorrow (today). I want to be sure i have the pump/load center pairing straight and I'd appreciate your double checking. I should...
  22. Poolsnip.JPG

    Poolsnip.JPG

  23. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    It is either late or i'm just not getting it and i apologize. It seems i could set times for the pump to run on A and times within A to run the pump on high using timer B. Is that right? Couldnt the SWG get wired to the same timer as the pump on timer A? Or is it the wattage that's too...
  24. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Is there anyway to trigger the high speed manually only when desired? Say i want to run the low speed for 6 hours a day and high only when desired like during or after a heavier load. It looks like i'll be going with the two speed pump. The solar idea is not as traditional as most systems and...
  25. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    A 60 amp service to the load center is just a double pole breaker running two hots to the new panel which isn't hard. Since it will be no further than 5' from the main panel i plan to run 10 gauge wire? I'll have my electrician do the final attaching i'll just get the wire close. Also with...
  26. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    This is where i'm realizing I need to talk with my electrician. I'm over here looking at UF-B 12/3 (made up of THWN wire) and not realizing when I said to "pull individual wires" i meant THWN wire. I'd gladly pull a neutral at the same time. Plus THWN wire is cheaper ($.30/ft) vs UF-B...
  27. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    @Jimrahbe - Thank you so much for your detailed reply. One thing that has pushed me to the Pentair line is their reputation. I was hard pressed to find much about AquaPro and for similar money I can get a 2 speed pump and a BIG cartridge filter (Pentair or Sta-Rite seem to be the two i'm...
  28. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Question 3 - Wire gauge from panel to pump? The run is about 25-30'. I'm thinking 12/2 or 12/3 depending on pump requirements. If i need to run that i'll likely run a 3/4" pvc conduit to allow for pulling two romex wires and possibly the pump comms wire back inside.
  29. J

    VSP & Filter Advice For AGP with CircuPool SJ/RJ-20 SWG

    Hello TFP members! Fun Joke to start this thread. What does a Mermaid say when she gets stuck in seaweed? Kelp! Kelp! (Courtesy of my 8 year old daughter). I've spent the last few days reading just about non-stop on here and I am moments away from pulling the trigger on an AG Saltwater...
  30. pool.JPG

    pool.JPG