Search results

  1. D

    Pentair Intelliflo VS Over Current Error

    I am having a similar issue to ones I have seen posted. Pentair Intelliflo VS pump hitting Over Current error. It appears to hit this error when the pump tries to ramp up quickly to scheduled higher speed at startup after priming. I am able to slowly ramp the RPMs up in Service mode and the...
  2. D

    Pentair Mastertemp 400 - Not igniting No errors

    I have a Mastertemp 400 that is not igniting. At startup the blower does not turn on. No errors on LED Panel or on board. No lights on ICM. I direct wired the blower to ICM and the blower does power up, but still no ignition. The article I was following stated if blower works with direct...
  3. D

    Pentair LA01N Booster Pump receiving power but does not start (no movement or sound)

    I have an LA01N that just stopped working a few days ago. I have tested that it is getting 240V at the contacts and have replaced the capacitor under the top cover. Is there anything else I can check or am I looking at a bad motor? If I replace the whole pump, do I have to go back with...
  4. D

    Can I add a 20 amp circuit to my Easy 8 Control Load Center for outlet and light in pool shed?

    I have a 25K gallon in ground pool/spa with Pentair equipment (VS pump, booster pump for cleaner, matertemp heater, led lights). All equipment is run through an Easy Touch 8 control load center. The load center is connected to a double pole breaker (50/50 amps) in my main house panel. The...