Search results

  1. C

    Pentair LED light issue

    This light flashes on-off-on-off-on-off during the relay "toggling" process (supposed to remain dark), and will not change to a different color selection. Just checked and it is on the same relay as the other 3 lights that are working properly, so it has to be the electronics in the light...
  2. C

    Pentair LED light issue

    Hi everyone, I'm having an issue with one of our Pentair microbrite pool lights. When I go to change the colors, this particular light flashes on and off as the relay resets, and will not accept a new program. Does this sound like a bad relay or a bad light?
  3. C

    Autofill leaking

    Thanks for replying. The auto leveler has worked quite well with the exception of the leak caused by the crack in the PVC fitting. What a ridiculous amount of hassle caused by one small part that isn't replaceable without major destruction. I think they're going to have to remove at least one...
  4. C

    Autofill leaking

    Hello TFP readers, we built a pool which was completed last summer, and signed off on taking possession of it on 8/16/2019. Less than a month later, we found that the pool was overfilling and I discovered that the built-in autofill had a crack in the PVC fitting. I posted about it on TFP in...
  5. IMG_3199.jpg

    IMG_3199.jpg

  6. IMG_3197.jpg

    IMG_3197.jpg

  7. D6DAA7BB-4723-49D0-82BE-511FC24726AE.jpeg

    D6DAA7BB-4723-49D0-82BE-511FC24726AE.jpeg

  8. 7E73CB9A-8FAA-4665-A698-46A0AE49B894.jpeg

    7E73CB9A-8FAA-4665-A698-46A0AE49B894.jpeg

  9. C

    Actuator for suction cleaner/skimmer valve

    Yes. I added an entry under pumps for “cleaner.” Now I can run pump at 2700 only when I’m running the suction cleaner instead of at 2700 all the time. Probably save me a bit on electricity since I can toggle pool down to 1800-2000 now and even run for more hours. As for circuit function...
  10. C

    Actuator for suction cleaner/skimmer valve

    One more quick question, if anyone has a moment :) Does it matter in SLConfig if I use "floor cleaner" for the circuit function or "generic"?
  11. C

    Actuator for suction cleaner/skimmer valve

    Well, I accomplished the swap. It was much easier than anticipated. I am not sure why the pool builder originally thought the bubblers needed a motorized actuator to toggle between the bubbler line and the dump line, when that valve is basically a set and forget valve. Now, I can easily schedule...
  12. IMG_2433.PNG

    IMG_2433.PNG

  13. C

    Actuator for suction cleaner/skimmer valve

    I had a thought today... Does anyone ever put actuators on their valve between their skimmer and suction cleaner, so that they can have their automation system go into a daily "cleaning mode" for a couple hours a day (25% suction to skimmer & 75% suction to cleaner) and then switch over to full...
  14. C

    Pentair temp sensor

    Found it. It may have been getting some extra sun due to the current sun angle, or the heat is reflecting off the wall behind it. Right now it’s shady at the panel and it’s reading 72 which is pretty accurate. An easy swap though if necessary now that I know where it is. Thanks for the help!
  15. 839C7170-1806-4BE5-AB5C-AC5FF4019EE3.jpeg

    839C7170-1806-4BE5-AB5C-AC5FF4019EE3.jpeg

  16. C

    Pentair temp sensor

    Quick question. We have an Easy Touch panel with Screen Logic interface on iPhone. Recently the air temperature has started reading high by about 10-20 degrees. Is the temp sensor for the water also the air sensor? I can’t locate a separate air sensor. Water temps seem correct.
  17. BCED97E8-9DD7-4C48-9881-1A1202597E1D.jpeg

    BCED97E8-9DD7-4C48-9881-1A1202597E1D.jpeg

  18. C

    Pentair IC40 reading zero salt

    Pentair replaced the switch under warranty. All good now.
  19. C

    Pentair IC40 reading zero salt

    That's what I gathered. I'll contact the Pentair rep.
  20. C

    Pentair IC40 reading zero salt

    Our pool was just refilled and our SWG is reading 0 PPM salt and the red “low salt” light is on. The proper salt level in the water has been verified. Our pool is 11,200 gallons and 8 bags of salt have been added/11.2k gals. Thinking this had something to do with the cold temps (water is around...
  21. C

    Plaster questions

    Thanks.... I will reach out, if for nothing more than to document it on my end for future warranty claims. It was plastered on a very hot day and I suspect that contributed to it.
  22. C

    Plaster questions

    We just had our pool built last summer, and the color was mottled and somewhat uneven... not severely but I wasn’t thrilled. The builder called the plaster contractor to have them work on the plaster. This week the pool was drained by the plaster company and, as it turns out, the entire pool...
  23. IMG_2025.jpeg

    IMG_2025.jpeg

  24. IMG_2027.jpeg

    IMG_2027.jpeg

  25. IMG_2021.jpg

    IMG_2021.jpg

  26. IMG_2023.jpeg

    IMG_2023.jpeg

  27. IMG_2015.jpeg

    IMG_2015.jpeg

  28. IMG_2013.jpeg

    IMG_2013.jpeg

  29. IMG_2003.jpeg

    IMG_2003.jpeg

  30. IMG_1998.jpeg

    IMG_1998.jpeg