Search results

  1. P

    placing foam on a pool's floor and walls

    I have a problem with vermiculite slopes after a winter without a liner. Would it be cheaper to put fresh vermiculite patches on the top of the old vermiculite, and then put a foam cover on a pool's floor and walls to cover small and big imperfections? Then I do not need to do a perfect job with...
  2. P

    inground pool shape - which is more practical?

    I have a concrete floor with vermiculite slopes. The vermiculite needs repair after a winter without a liner. It also makes complicated to measure the right size for the liner replacement. Is there any practical reason to have the shape A instead of the shape B? Is it a good idea to remove...
  3. P

    How to make pool stay warm for long?

    Does it make sense to place a pool wall foam? My pool walls are made of some sort of plastic. Will the foam insulation help much? The pool floor seems to be made from concrete. Is it possible to place this wall foam insulation on the pool floor? Thanks.
  4. P

    How important to treat remove mold before installing a new liner?

    What is the best way to clean it? Spaying an algaecide and power washing? Thanks.
  5. P

    How to find the sizes on the installed liner to order a new one for an inground pool?

    Do the vinyl liner manufactures place the specific sizes on any side of the liner? Thanks.
  6. P

    Automatic cover replacement rope buying

    What type of the rope do I need to buy and where?
  7. P

    How to clean the automatic pool cover rope and the rope track?

    I have a trouble to close automatic pool cover all way down - too much tension. I jet sprayed it with garden water hose - got a lot of dirt out but still it does not slide smoothly. Is it any way to clean it more efficiently? Any special chemicals? Enzyme cleaners or etc? What would you recommend?
  8. P

    Swimming pool enclosure

    How expensive to build an enclosure around the pool?
  9. P

    Pentair MiniMax NT pool heater - top cover cleaning

    How to clean the top of the heater?
  10. P

    Pentair MiniMax NT does not ignite - error E05

    The green lights go upto "HEATING" I can smell gas from exhaust after “HEATING” goes green for 2-3 sec. After 3 attempts, it shows Error E05. 70V comes to my igniter. Should it be 120V? I also measured that the igniter has 100 Om resistance. Is it normal? Is it a false igniter or board...
  11. P

    CoverPools broken rope (inground, rope in the wall)

    How to fit a new rope into the rail? Do I need to remove the rail from the wall?