Search results

  1. T

    Dead end run after return line

    Is a dead end run recommended after a return line that terminates at a wall fitting? I seem to recall reading that somewhere, but can’t find the post now.
  2. T

    Winterization of Jandy valves

    I’m getting ready to install a Jandy valve in a horizontal position (handle parallel to the ground). When winterizing, there appears to be the possibility of a small amount of residual water left in the bottom of the valve. Would the internal valve mechanism be damaged when the small amount of...
  3. T

    Wye manifold vs tees

    What is a better way to go when taking two 2” return lines into a single 2” pipe leading my to the pump—a wye manifold or tees? I ordered a wye manifold and the entire manifold is smaller than I had imagined, as are the openings inside. The openings are essentially a couple rounded off...
  4. T

    Distance between sand filter and pump

    Is there a maximum distance a pump can be from a sand filter, or would some water flow issues arise? I’d like to move my pump about 15-20 ft away from my sand filter. I’ve searched online and can’t find an answer to the allowable distance. Any thoughts?
  5. T

    Anyone have trouble with installing a skimmer above the weld line on an Intex pool?

    Split from Thru Wall Skimmer Install. Above Seam & With Intex Hoses I’m considering installing a skimmer above the seam as well. Has anyone experienced any problems with the integrity of the liner due to cutting through the welded seam?
  6. T

    Use pad in addition to foam?

    Would laying a pad down on top of extruded polystyrene provide any advantage for an Intex Ultra XTR liner, or is it simply redundant?
  7. T

    What keeps water out of Intex sliding corners?

    The Intex rectangular pools use a sliding corner that is designed to move with the pool. What, if anything, keep water from getting in via that connection and flowing into the adjacent U leg? Without weep holes in the bottom of the U leg, wouldn’t water just sit at the bottom?
  8. T

    Intex Ultra XTR and frame rust

    We have a 9 x 18 Intex Ultra XTR on the way and I’m exploring options to minimize frame rust. I understand these are now powder coated on the inside, but I’m debating applying POR-15 as well. https://www.google.com/amp/s/www.por15.com/POR-15-Rust-Preventive-Coating%3famp=1 I’ve also read...
  9. T

    Concrete Block Pool Build question

    This post was moved to a new thread. Please click link for information from the original thread. Zea3 New concrete block pool build Sorry to dig up an old post, but I've been researching concrete block pools. The part that has me worried is the floor and wall connection, and waterproofing...