Search results

  1. G

    Connection from pool sub panel to heat pump

    I am planning on a heat pump. I cannot place it close enough to the panel or anywhere else to use a 6 foot liquid tight whip (9 feet from panel). Is my only option to run pvc or rigid conduit underground close to the heater? If yes, do I transition to liquid right through a junction box...
  2. G

    Outdoor pool sub panel

    Is there a minimum height above ground for an outdoor pool sub panel? Also, can the sub panel be a disconnect for both the pool pump and the heat pump (using the two circuit breakers) or will they need separate disconnects in addition to the sub panel? Thx
  3. G

    Heat pump flow and pressure loss

    I’ve been looking for any documentation on flow and pressure loss for the Hayward W3HP21405T and can’t find it. I can find it for the Raypak 8550, which is the other heat pump under consideration. Does Hayward publish this data? Thx
  4. G

    Heater Bypass?

    I know this is a bit off subject, but I just put in a bypass because I will be installing a heat pump. I am down to a Hayward and the same Raypac you installed. It may be too early, but do you have any advice/opinions on buying the Raypac? Thx Moved from here.
  5. G

    Hayward Tristar 900 vs 950

    Hi. I’ve read previous posts on the comparison, but can’t get a good feel for which pump. I’ve done the head calculations and the 1.85 HP is fine. I would consider the 2.7 if it is significantly more quiet because it may run at a lower speed (neighbors 🙄). I am installing myself so the Pentair...
  6. G

    Another Heat pump Recommendation

    I am redoing all my equipment. I am now at the point of picking a heat pump. We are in NJ, just want a warmer pool during the summer and extend the session a week or two. I am looking at Aquacal and Raypak. Reliability is important, but since the equipment is close to the property line and...
  7. G

    Aquastar PLF35000

    Anyone using this filter. I was about to order a Hayward C4030, but this filter looks pretty easy to clean. Might be too small for my pool and not sure how it will hold up. Also not a whole lot of reviews for it. Thx
  8. G

    Bonding question

    Hi. I am replacing a pool pump on an older pool and noticed there is no bonding wire at the pump. I checked the pool. The ladder, handrail and pool light junction box had continuity, so it looks like it has a bonding grid. I will check to see if the pump bonding wire was cut. My question is the...
  9. G

    Leaking pool wall fitting

    After losing water for a few weeks, I pressure tested my pool and found a leak at the pool wall. There is 1 1/2 inch black poly pipe that attaches to the wall over a plastic fitting. The black poly was glued on and the fitting is cracked. It looks like it is a reducing fitting that reduces...
  10. G

    Pool Pump Sizing

    A question asked a thousand times, I am sure. My Pentair 1.5 HP Challenger pump motor just failed. I've replaced the motor twice and the pump is quite old, so I am looking at another pump. My pool is 26,000 gallons, 1.5 inch piping, 1 skimmer, 1 drain, 2 returns, a Nature II and chlorinator...