  1. L

    D.C. Voltage.

    I periodically check my pool for stray voltage just as a precaution.I accidentally had my meter on D.C. And noticed 25v DC with one probe in the water on the other on the painted deck.No AC voltage.Maybe it's always been there. Thanks Tom
  2. L

    Hayward swg dead

    My Hayward swg glx has power but nothing comes on,can someone tell me how to troubleshoot it. thanks,Tom
  3. L

    Gfi on pump

    I have a inground pool that came with the house I bought 3 years ago.It has a 110 volt pump hard wired to a weather proof timer and to circuit panel.It is on a 30 amp gfi breaker.I think during a storm it is tripping.I replaced that gfi when I bought the house.Do I really need a gfi if the pump...
  4. L

    D.C. Voltage

    Not sure if I have this in the correct section.I was having bonding issues last year so periodically I test the water for any voltage,all has been well.Today I tested it and by mistake I had my meter on D.C. And recorded .25 volts.Whats up with that?Salt system pool,using digital meter.
  5. L

    Closing pool in alabama

    I live in central Alabama where it can get 18 degrees or 80 degrees during the winter.I will be away from home Jan thru March.I have a inground salt system pool and no one to look after it.What do I do? Thanks in advance,Tom
  6. L

    Poor vacuum suction

    I have a 24000 gallon vinyl inground pool,1.5 hp motor that's 12 years old.Motor seems to pump lots of water,but not much sucsion on hand vacuum.The only valves I have is a little on in skimmer but turning it does not seem to change things.Liner replaced last year,sand filter cleaned a filled...
  7. L

    What's causing this voltage

    I have a inground vinyl pool with concrete deck.I bought the house about a year ago pool was installed 10 years ago.Alabama is a non disclosure real estate state.We were told by a neighbor there was a tingle.We just started using pool 3 weeks ago no one has felt a tingle except my 4 year old...
  8. L

    Another bonding issue

    I. recently purchased a home in Alabama with a in ground vinyl pool.It has a 3 foot wide concrete deck all around pool.I was not told by the seller their was a tingle in the pool.I can turn off main breaker to all of the system,put a volt meter probe in the water,the other probe on concrete deck...
  9. L

    Salt readings

    I just had my pool liner replaced(I ground approx 26,500 gal.I put in 18X40lbs of salt.)Pool temp is 60 degrees and on a test strip it reads 1600 but on my Hayward generator it reads 3400.also I started generating today and have it on and panel reads 60% and stays there and does not return back...
  10. L

    Salt generator issue

    I just purchased a home from an estate so no one has knowledge of pool.I repaired the circuit board,all lights are working fine but salt reading is at default of 2500.After it cycles I get solid red hi salt reading and generator light goes out.I tested water with salt test strip and it reads...