Search results

  1. N

    Help with SWG

    Just to clarify, the sock you have in there now is adding what you needed to get to a CYA of 40 still? If so then leave it and assume you are at 40. If already working to bring it up to 70-80 though I'd get it pulled out.
  2. N

    Pressure pump pressure relief purpose?

    I'm just wondering about the pressure relief on my Polaris wall fitting. Is that to protect the Polaris, simply to have the "correct" pressure where the Polaris works best, or does it protect the pump? I haven't had anything to mess with on my pool for awhile and bored so going to make an...
  3. N

    Help with SWG

    I forgot about the pucks. If you lost 1ppm even with those in there along with knowing your FC has been below minimum I'd go ahead and start a SLAM while your CYA is still in a decent range to do it. It shouldn't last long but give some piece of mind before bumping that CYA up. As for pool...
  4. N

    Help with SWG

    Do you have your SWG turned off right now, or at least when you did the OCLT ?
  5. N

    Estimating pool size

    Some of the math wizards will be able to help get it close. For a ballpark range though I used FC and pool math. I tested FC with the 25ml sample. Added a known amount of bleach and tested again after it was mixed. I put those in as current and target, then changed the pool volume up above...
  6. N

    Helping a friend with her solar panels

    We bought a new house a little over a year ago and looked at almost a dozen home inspectors online to pick one. At least in our area every single one had a disclaimer on the pool portion. Some wouldn't inspect it at all, some said it was a courtesy with no guarantee, and some charged a small...
  7. N

    Installing commercial chlorinator

    http://www.pentairpool.com/pdfs/ChlorineBromineIG.pdf The inlet line, (control valve side of feeder) connects to the plumbing between the pump and filter. The outlet side of the feeder connects to pool return line after the filter and/or heater, pool cleaner, diverter valves or any other piece...
  8. N

    Installing commercial chlorinator

    Between the flow meter and ball valve so closing the valve just slightly would cause water to flow through the clorinator I'd think would work. Or, add a valve just beyond where it ties in one one side you could close just a bit. Do either of the two legs run to something further down that...
  9. N

    hard plumb and LIQUIDATOR Install (HELP NEEDED)

    If I am understanding your issue it sounds like you need the unions? Item 16 in this? Hayward Matrix Pump Parts - INYOPools.com
  10. N

    Installing commercial chlorinator

    Ummm. The return goes to a tee. Each side of the chlorinator goes to one side. Wouldn't both sides have equal pressure? How would anything ever go through the chlorinator? And how've you been doing Justin? Good to see you! Hope you remember all that fun digging in my yard anyway, lol.
  11. N

    Bought a foreclosure that included a 33,000 gallon, p.i.t.a., frog hatchery

    My "I hate math" method was to test FC, add chlorine, short while after test FC again. Put those in pool math as current and target, then play with the pool size until the recommended amount equals what you actually put in :) You'll be consuming chlorine, but 15 minutes or so for it to mix it...
  12. N

    Helping a friend with her solar panels

    While labeling the suctions side as "jets" is odd, the second pump appears to be dedicated for the spa jets.
  13. N

    How to remove and clean a hayward t-cell-15

    Aqua Rite I think is what comes with just the SWG package, or could be an Aqua Logic for that and other controls. Here's the Aqua Rite How To Recalibrate the Salt Level on a Hayward Aqua Rite - INYOPools.com Aqua Logic (most versions) page 14 here...
  14. N

    How to remove and clean a hayward t-cell-15

    Resetting or re-calibrating the controller may help. What controller are you using and can you check the instant salt reading?
  15. N

    CYA test with R-7065 standardized solution - Huh?

    The instructions say to use it in place of the pool water and still add the R-0013.
  16. N

    Lazy Man's Pool, the ultimate in Trouble Free Pool :)

    LOL, that and it's too dang hot out to be fighting with moving it, plumbing, and electrical when a pool is so close by!!! Better have it ready for Fall though!!
  17. N

    Cloudy Blue Water

    You already have the test kit so ready to roll :) You're going to need to SLAM it though :( Pool School - SLAM - Shock Level And Maintain You'll need to get the PH down to 7.2 before starting and CYA around 30. With what you already added you should be pretty close to 30. With it being...
  18. N

    pH continues to fall

    Every pool is different and finding the equalibrium is more important than a stated range. Pool School also says "sometimes higher". A higher TA will result in PH rising more easily, or in your case hopefully not drop as fast. It is also a rule of thumb and only recently did they drop the...
  19. N

    Salt VS Chlorine

    Pool School - Salt Water Chlorine Generators Also, a salt pool is a chlorine pool as well, only the source of the chlorine is different.
  20. N

    Question about Chlorine levels based on CYA and "Recommended 4ppm guidelines"

    Re: Question about Chlorine levels based on CYA and "Recommended 4ppm guidelines" I can't find it now or recall where I once saw it. I was reading Chem Geeks stuff, then links he provided, and surfed on from there, but I swear I read somewhere that the EPA never did ANY studies whatsoever on...
  21. N

    27,000 gallon inground 16x41x32 Vynal saltwater. That's how I found this place!

    The SWG is making chlorine then. The problem is it's being consumed too rapidly and can't keep up. You're going to need one of the recommended test kits and SLAM the pool. The instructions are here: Pool School - SLAM - Shock Level And Maintain Read it a few times as well as the rest of...
  22. N

    Lazy Man's Pool, the ultimate in Trouble Free Pool :)

    LOL, well, if the SWG adds it then I still didn't add anything :)
  23. N

    Bought a foreclosure that included a 33,000 gallon, p.i.t.a., frog hatchery

    YAY!!! We like pictures :) Looks like you already have a leg up on it and a good start. Once you have test kit in hand and know the laundry isle employees personally from bleach runs your wife will be happy to finally use the dang pool! :)
  24. N

    Aqua Logic Controller Question

    When you don't see stats, back on the default menu is it showing a "No Flow" condition? Perhaps the low speed is just borderline for providing enough flow. Does it show no stats at all, or zeros? Does it improve after backwashing or cleaning the filter? Those of us with a variable speed can...
  25. N

    Bought a foreclosure that included a 33,000 gallon, p.i.t.a., frog hatchery

    Uploading them to Photobucket and then just pasting in the IMG code it provides works well. Here's the tutorial on it. Posting Photo's Tutorial And welcome to TFP :)
  26. N

    Water turned DEEP BROWN in 2 days! Help! New Pool & NPO

    Turn off the SWG, it won't help much at those levels and only use up some of its life and also make it hard for you to know how much you are really losing. The more often you can test and bring FC back up the quicker it will go as well. Once you pass all three tests and let FC come back down...
  27. N

    Water turned DEEP BROWN in 2 days! Help! New Pool & NPO

    Ooops, wrong link, sorry!! Pool School - SLAM - Shock Level And Maintain
  28. N

    Water turned DEEP BROWN in 2 days! Help! New Pool & NPO

    It looks like you went from an iron problem into an algae problem due to low FC. I don't know how some walk people through it so easy, but while you wait you might as well read this a couple of times :( Pool School - Chlorine / CYA Chart
  29. N

    Low pH AND low TA? - SWG Vinyl Intex 10,000gal

    That PH with an SWG is odd, has any other chemicals been used in the past? I would use pool math and add enough borax to get it to 7.4 and if it continues to drop then raise the TA but I wouldn't add anything to TA intentionally for now. Or even better get some aeration of some sort going to...
  30. N

    Intellichlor IC40 Low Salt but reads fine

    Hopefully someone who knows Pentair comes along soon :) I'm pretty sure the temp and flow are all in that one switch and they just replaced it though. Unless they got a couple of the four wires swapped around it should eliminate that as the issue.