Old motor looks like a two-speed motor that was wired for one speed only. If the new motor hasn't been damaged by the way it is now wired, and is a single-speed motor, move the wire from terminal 2 to terminal 4 and it should work.Trying to replace 220v single phase motor but wiring is different on Motor I purchased for replacement
This is how it was
View attachment 644012
New motor has #1 #2 #3 #4 Old one only had A and B
This is the way I wired new Motor but doesn't work
Am I wiring it wrong ?
View attachment 644011
Can anyone help Please
Thank you for respondingWelcome to TFP.
What model motor are we discussing?
Show us pictures of the motor data plates on your old and new motor.
Welcome to TFP.
What model motor are we discussing?
Show us pictures of the motor data plates on your old and new motor.
Old motor was a 2.6 total horsepower motor. New motor is a 2.2 total horsepower motor based on all the pictures of the rating plate on E-bay of the motor with that number. It won't last long if the impeller isn't changed. The new motor is for a 1.5hp full-rated, 2hp up-rated pump, a WFE-6 was the full-rated version. You have a full-rated pump, a WFE-8.Thank you Very Much!
I will try your suggestion
Thank you for responding
This is a picture of old motor
View attachment 644173
Here are specification on New motor. I will take a picture of plate this evening
View attachment 644174