- Jul 23, 2024
- 42
- Pool Size
- 5500
- Surface
- Fiberglass
- Chlorine
- Salt Water Generator
- SWG Type
- Hayward Turbo Cell (T-CELL-5)
Here are my results while opening the pool.
The pool company came to open it. They put some CalHypo in it (shock).
These are my results after testing with the Taylor kit.
I decided to treat the pool by myself (pool company was saying never put liquid chlorine) but I trust TFP most.
I was thinking of balancing pH before and putting a bit of CYA (no clue what the actual CYA is, water is a bit cloudy once the water is at the 30 mark on the taylor kit, it was 30 before closing).
I guess putting the pH down will take care of the TA.
So once pH and CYA are in line, I would slam the pool because it is cloudy.
The pH was 8 or over (can't know exactly) and the acid demand tests was 7 drops (so for my 5000 gallons Taylor says 1qt (1L) of 20 baume muriatic acid)
here are photos of the pool yesterday (before opening) and today
I have scrubed, vacuumed and cleaned the filters.