Pentair Pump issue

CatalanBull

Bronze Supporter
Apr 3, 2025
25
Corona, CA
Pool Size
13500
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-40
Hi,

This past week I’ve been dealing with a couple of issues with my Pentair Easytouch system and the 011018 pump.

The scheduling of the Easytouch seems to be malfunctioning: whenever I change the start or end time of a schedule while it’s running, the schedules randomly turn off afer a few hours. However if I adjust the schedule before it starts, everything works fine. While troubleshooting I found an Easytouch motherboard for $400, which I think is a good price, thinking I might need to replace it. But since adjusting the schedule before it starts works, I’m not planning on replacing it for now.

Also my Pentair 010018 Pump started making a loud squealing noise. Not always, but intermittently. After reading in this forum it seems that pump replacement might be the best option. However, before I replace it I want to use the current pump for as long as possible. I found that the discontinued VS 011028 pump could be a drop-in replacement, but I can’t find it at a reasonable price. The next option I’m considering is the Intelliflo 3 VSF. From my research, it looks like for it to work with all features my Easytouch needs to be on firmware version 2.16. Currently I’m on 2.13, but the motherboard I purchased is at 2.18. I still have time to return it, should I keep it for when I replace the pump, or is there a better plan? I don’t know how difficult it is to update the firmware of the Easytouch. I don’t have screen logic and I’m not planning on putting it in, unless I really need to or makes sense for the price.

I have the pump on 24/7 at 1700 RPMs, with 5 hours at mid day at 2700, I’ll reduce the 5 hours to 2, in hopes to elongate its life.

Any advice or suggestions will be as always appreciated!

Thanks!
Roger
 
Roger,

Depending on when you adjust a schedule on the EasyTouch it 'may' take up to 24 hours to catch up.. What generally happens is that the system will miss a shut off and then it will continue to run until the Egg-timer shuts it off.. Egg-timers have a default value of 12 hours..

Anything you manually turn on will run for X amount of time based on what the egg-timer is set for..

I don't think you have a bad EasyTouch board..

Here is where I buy my equipment...


That said, your pump is old, and the replacement is just as old, and I don't think even made any more.. :(

Thanks,

Jim R.
 
Full details of EasyTouch firmware versions can be found here.

I do not see any pump changes between 2.13 and 2.18 other than they fixed several issues with the VSF pump
 
  • Like
Reactions: CatalanBull
Thanks Allen, so since it seems like the VSF pump is the one that will eventually replace my current pump I should probably keep this 2.18 motherboard. Thanks!
 
Roger,

The IntelliFlo3 is a great pump... But, it is not a drop in replacement for your 011018.. One of the two ports does not line up, so a little replumbing will need to happen to make it fit.

When my IntelliFlo bites the dust, I plan on installing the IntelliFlo3 also..

Keep in mind that it comes as a 1.5 HP or 3 HP model.. I never recommend smaller 1.5 HP VS pumps..

Thanks,


Jim R.
 
  • Like
Reactions: CatalanBull