Looking for your valued input on our in progress gunite pool renovation in frost thaw climate Central NJ. The demolition of our former cantilevered concrete decking is complete and this week the PB will begin on removing tile and get to starting the renovation work.
In trying to understand the materials that will be used (reading the TDS). In phone discussion it does not appear that the PB is aware of the TCNA EJ171 Movement Joint guidelines for exterior applications for ceramic and stone, the location and the frequency of these soft joints are called for every 8 ft to 12ft depending on the materials and environmental conditions. We HAD for 21 years tile that never came off the pool (including through this weeks jackhammering!) and back then with the cantilevered deck and NO coping - we had no soft joints in the tile. Now wondering since we will have 12X24x1.5 inch thick granite coping and will be using a 6X6 THROUGH BODY Porcelain water line tile on this renovation, should I be pushing the PB to put in the soft joints if it hasn't been their practice? If I am understanding properly the "soft joint" would be a 100% silicone material and would be in the TILE and then Up through the granite coping stone, too. IS this something to insist on or is it something to go not have and then down the road IF there is cracking, deal with later (not preferable). Not sure if we are allowed to mention product brand names here so want to be respectful. THANK You all in advance
Picture of pool to be redone below so you can see the raised wall of tile too.
In trying to understand the materials that will be used (reading the TDS). In phone discussion it does not appear that the PB is aware of the TCNA EJ171 Movement Joint guidelines for exterior applications for ceramic and stone, the location and the frequency of these soft joints are called for every 8 ft to 12ft depending on the materials and environmental conditions. We HAD for 21 years tile that never came off the pool (including through this weeks jackhammering!) and back then with the cantilevered deck and NO coping - we had no soft joints in the tile. Now wondering since we will have 12X24x1.5 inch thick granite coping and will be using a 6X6 THROUGH BODY Porcelain water line tile on this renovation, should I be pushing the PB to put in the soft joints if it hasn't been their practice? If I am understanding properly the "soft joint" would be a 100% silicone material and would be in the TILE and then Up through the granite coping stone, too. IS this something to insist on or is it something to go not have and then down the road IF there is cracking, deal with later (not preferable). Not sure if we are allowed to mention product brand names here so want to be respectful. THANK You all in advance
Picture of pool to be redone below so you can see the raised wall of tile too.