The power light is on, but when you switch from off to auto there is no click. nothing happens, it doesn't generate. None of the other LEDs come on. The no flow does not come on when pump is off . Display works fine. Salt reads zero. I checked the back of the board and it looks good, no burnt spots. I had a black thermistor and replaced it. Tested voltage with a multimeter , using the information from http://www.haywardnet.com/pdfs/Aqua_Rite_1.59_Troubleshooting_Guide, everything looked good except the reading from the orange wire to the green ground lug was 26.3VAC instead of 10-14 VAC.
also tried a new T 15 cell, nothing changed.
Any help would be appreciated. Thank you