Pool Pump blew up in my face - lucky I'm tall!

viking68

0
Silver Supporter
May 9, 2010
69
Lake Mary, FL
So, I glance out at the pool this a.m. - pump's not on. Hmm...investigate...hmm....timer is stopped - in the power on position...hmm...check outside breaker - not tripped, reset. Nothing. Hmm...reset inside breaker, also not tripped...hmmm.

Flip power switch. BANG! SMOKE! Then look down:

20170409_110113.jpg

20170409_110122.jpg

Not quite 3 Year old 1HP Pentair SuperFlo.

Replace motor? Replace pump with Vari-Speed?

Why does this stuff always happen on the weekend? Water Chemistry is PERFECT thanks to the education I received here.

Thanks for any/all comments. Think maybe capacitor went, then forced into overload when I reset everything?
 
Wow! Good thing you are safe for sure. If you don't have a bunch of water features or spa, you could just replace that motor with a nice 2-speed for efficiency. VS pumps have their advantages as well, but owners usually balance up-front costs to efficiency of managing multiple flow settings to run various areas of the pool/spa. Yes, always on the weekend. :hammer:
 
Wow! Good thing you are safe for sure. If you don't have a bunch of water features or spa, you could just replace that motor with a nice 2-speed for efficiency. VS pumps have their advantages as well, but owners usually balance up-front costs to efficiency of managing multiple flow settings to run various areas of the pool/spa. Yes, always on the weekend. :hammer:

Old pool - pump only runs 3 jets and skimmer, Period. Main drain has been blocked with sand (thank you old, old marcite) for years. Polaris booster bleeds off some for the 280 running around the pool. Can you retrofit a 2 speed onto a superflo pump?
 
Some of the others here are really good on pump swaps and such. If you don't get a reply here, you could call Inyopools with your pump info and they'll give you some good dry-end motor replacement options based on required HP, speeds, and flow. They're very good with TFP members.
 
My first call tomorrow AM would be to Pentair Tech support asking them where to email those pictures and to whom you should speak to about replacing that pump.....for free.

I think they will do so quickly and quietly
 
Yes. Is the motor wired for 230v or 115v?

I can wire a motor (done the Polaris Booster pump twice in the last 14 years); special wiring or timer setup for 2 speed? Pool only has 3 jets and a skimmer - nothing else.

According to specs, this is an up-rated 1hp/1.25SF or 3/4hp/1.67 full rated. Which the heck motor should I go with for a 2 speed?
 

Enjoying this content?

Support TFP with a donation.

Give Support
My first call tomorrow AM would be to Pentair Tech support asking them where to email those pictures and to whom you should speak to about replacing that pump.....for free.

I think they will do so quickly and quietly

Dave, and here I thought I was so smart! GENIUS! Local builder that built this pool as well as a new pool at my old home is my "go to guy". Never ever thought about going to pentair direct!

Very weird the way everything happened - NOTHING in the house was affected so I don't think there was any kind of surge/spike, timer was in "on" position (which was very odd) and the pump was off. It wasn't until I reset both breakers and turned time to on position that I "JUMPED BACK, JACK"! Something in the motor is definitely screwy. Less than 3 years old.

Thanks so much for that kind piece of advice.
 
Very weird the way everything happened - NOTHING in the house was affected so I don't think there was any kind of surge/spike, timer was in "on" position (which was very odd) and the pump was off. It wasn't until I reset both breakers and turned time to on position that I "JUMPED BACK, JACK"! Something in the motor is definitely screwy. Less than 3 years old.

From the looks of the paint and label on that motor, it looks like it has been struggling for a while, and finally gave up. It died the first time with a wimper, and simply tripped a breaker. I know you said that they weren't tripped, but possibly only one of the poles did, which depending on the breaker can make it look and feel like it was still on. The fact that your timer was stopped says no power. When you reenergized the circuit, the short was in just the right position to provide you with the flash-bang. Still, yeah, it's new motor time...
 
From the looks of the paint and label on that motor, it looks like it has been struggling for a while, and finally gave up. It died the first time with a wimper, and simply tripped a breaker. I know you said that they weren't tripped, but possibly only one of the poles did, which depending on the breaker can make it look and feel like it was still on. The fact that your timer was stopped says no power. When you reenergized the circuit, the short was in just the right position to provide you with the flash-bang. Still, yeah, it's new motor time...

See - that's the funny thing. I looked at the motor just before - all that damage is from electrical flash. It wasn't a "little" pop; blue arc/flame popped up at least 2' - I was looking right at it! I cleaned out the strainer a couple days before and it looked almost like new - its only 32 months old; last motor that this pump replaced, lasted 10 years + on a 16++ YO Sta-Rite Pump. Same 1HP AO Smith/Century motor.

It's obvious the cap blew too with all that black "drool".

Per Dave S., contacted Pentair - they are on the case; Now we'll see what they do...I'll update when I hear back.
 
See - that's the funny thing. I looked at the motor just before - all that damage is from electrical flash. It wasn't a "little" pop; blue arc/flame popped up at least 2' - I was looking right at it! I cleaned out the strainer a couple days before and it looked almost like new - its only 32 months old; last motor that this pump replaced, lasted 10 years + on a 16++ YO Sta-Rite Pump. Same 1HP AO Smith/Century motor.

It's obvious the cap blew too with all that black "drool".

Per Dave S., contacted Pentair - they are on the case; Now we'll see what they do...I'll update when I hear back.
This sounds like the cap is the failure. There really isn't anything else in that area that would explode, especially with an arc.
 
My first call tomorrow AM would be to Pentair Tech support asking them where to email those pictures and to whom you should speak to about replacing that pump.....for free.

I think they will do so quickly and quietly
Good advice. I agree...they should try to fix this very quickly based on those pictures. Scary stuff.

Mention that you were (almost) burned due to the motor explosion and I bet they move even faster to take care of your problem.

The potential for a lawsuit is a powerful thing!
 
UPDATE:

Pentair authorized service company is replacing the motor today, gratis. Initially, the repair agent tried to schedule me for NEXT TUESDAY. I replied to Pentair this was unacceptable, i.e.: this is Florida, it's hot, chlorine is likely depleted and pool will be green by next Tuesday. I added that next Tuesday is fine, if they then wanted to pay a local service company to re-balance the water chemistry, etc., etc.

Suprised by call from repair company this morning: "We'll be out there today!".

Thanks again to Dave S. - never would have thought to call Pentair direct on an almost 3 year old pump! I love TFP!
 
This sounds like the cap is the failure. There really isn't anything else in that area that would explode, especially with an arc.

Well, it's obvious the cap failed, but the cap housing is intact. The rear end of the motor BLEW OFF. The wiring is fried on the back - not up top, unless when the cap blew, it went down through the motor and out the back!
 
Capacitors contain an impressive amount of energy and when they fail they release all that energy in an instant. Its very likely that the metal top cap contained the blast and directed it down the wiring and out the back cover. Its also likely the cap continued to burn for a while after exploding giving you all that nice brown paint.
 

Enjoying this content?

Support TFP with a donation.

Give Support