    Pump flow

    It wound up being a bad pressure gauge. All the numbers make sense now. I cared about flow rate because the skimmer seemed like it wasn't getting enough flow as i had alot of surface debirs not being skimmed. I was thinking that the pump was not flowing as it should so I wanted to verify this...
  2. 20240529_182352.jpg

    20240529_182352.jpg

  3. X

    Pump flow

    Here is a picture. Maybe flow meter is too close to backflow preventer.
  4. X

    Pump flow

    Thanks. The curve came from an owners manual i had but I found a later revison of the the manual on haywards site and the curves are not shown. So I agree maybe they are not correct. I'm also now doubting the pressure gauge as I went out to check the zero reading which it is but when running...
  5. X

    Pump flow

    Hi, I have a hayward SP3007EEAZ pump which spring a leak in one of the seal so I got the rebuild kit and all is good I think. The pump is old and I think I suffer from low flow issues so I bought a flow meter and measure vac and filter psi and converted it to head pressure. The equation I'm...