Recent content by TexasEllis

  1. T

    Can a Jandy Filter Tank Collar Wear Out?

    Thank you both for your replies. I really appreciate it.
  2. T

    Can a Jandy Filter Tank Collar Wear Out?

    First off, thank you. DEL60 Yes, cleaned the clamp, O-ring and the plastic on top and bottom of filter where it seals. Yes, lubed O-ring and checked it. No damage. Rotated it but leak happened no matter. Filter instructions lost 17 years ago..... I cranked the S out of it tightening and...
  3. T

    Can a Jandy Filter Tank Collar Wear Out?

    This part. https://lesliespool.com/jandy-r0357400-replacement-tank-clamp-ring-with-knob-assembly/617074.html?msockid=21ef939c3c236ff02ca486c23d886e85 17 year old pool, never had a leak problem. Cleaned the filter today, put it all back together and once it's halfway full, start leaking at...
  4. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    OK! Finally got back to it. And y'all are gonna laugh but remember, I am a sales guy. Not an engineer. The board is fine. The circuits are fine. The chips are fine. I forgot to move the switch on the actuator valve. Genius, I know. :rolleyes: So everything is working. Special shout out...
  5. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    So I got pulled out of town for business and can't get to the pool this week. Hopefully this weekend. Thank you again ajw22!
  6. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    First off, you are amazing. Thank you so much for your help. Here is the board, First pic is looking towards the board as it is opened, the second looking down on the board. If that makes sense. I used the diagram on the link you sent but the salesguy in me isn't figuring out what part you...
  7. image000000.jpg (1).jpeg

    image000000.jpg (1).jpeg

  8. image000001.jpg.jpeg

    image000001.jpg.jpeg

  9. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    Yes it does turn. Driver chip is a new term to me. I understand what you are saying, just unsure of which chip I should purchase. Sorry to wear you down. Electronics beyond basics is confusing to this sales guy. Thank you again. My donation was done at 11:13, initials are JE.
  10. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    It's an Aqualink RS . Had the entire pump go out last year and the board needed to be replaced as well. If it matters, it's a Jandy Variable speed EPump model VSSHP270DV2A. And thank you again, especially for your prompt response!
  11. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    Just donated at 11:13 CDT! Glad I could help. Next question. I followed the wire to the circuit board and located the plug in. Took it off, plugged the new unit in before installing and it's not getting any commands from the board. Do I have to fully install the actuator valve for it to...
  12. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    AWESOME! Thank you so much! I love saving me some money!
  13. T

    Repair/Replace Jandy JVR-2444 Valve Actuator & Non-Jandy Models

    18 year old pool, believe the valve actuator to the spa is finished. Checked wiring, it all appears to be in good condition. Any suggestions on what else to check? Also, the replacement Jandy part is $200+.....there are identicals from Tork and this brand TPE24VA 24-volte pool valve acuator...
  14. T

    New Jandy Pump Not Starting

    Welp, circuit board out.......that solves that.
  15. T

    New Jandy Pump Not Starting

    I am running a new Jandy EPump variable speed system. Installed lass than a year ago. Running fine this morning, I shut it down to clean the salt cell. Once done, assembled the system but I think maybe the contacts on the salt cell were still wet/damp when I connected it all up because now...