Recent content by Tallpines

  1. T

    Near pool light tingling when pump is running

    We found the problems which was pointed out by a utilities tech that our main panel's earth ground somehow did not have a good connection to ground(based on his readings with a meter) . Part of ground cable was inside wall that made it hard to detect. The shock went away after a new ground wire...
  2. T

    Near pool light tingling when pump is running

    I apologize for a slow in response, we spent most of the day yesterday trying to do continuity and NEV test for all bonding and equipment. We drained water to have access to light niche and measured voltage of metal light niche in ref to ground, there was 5-7V AC present there with minor shock...
  3. T

    Near pool light tingling when pump is running

    very cool video from Mike Holt , thanks so much ajw22.
  4. T

    Near pool light tingling when pump is running

    Thanks for your input, all bonding seems to be in good working order. Pump is on GFCI CB and it never trips while this is going on. Lights were not on GFCI CB but i just installed a GFCI CB for lights. Had an electrician over yesterday and he said lights might be bad. He suggested that the whole...
  5. T

    Near pool light tingling when pump is running

    These are 120V lights. Thank you!
  6. T

    Near pool light tingling when pump is running

    Hi, I'm having some issues with our pool lights hope to get some info as to what might be going on here. The other day I found out that whenever I get close to both of the lights within a few inches, I felt minor shock. This happens only when the pump is running and even when there is no power...