  1. T

    Stay Rite Max E Therm 400 E 01 error code

    Quick Follow Up: As mentioned above, after changing thermister and letting the pool pump power up and cycle a few times, the heater started working properly. However, now, it will switch modes from pool to spa on its own. Also, if I turn it off, (heater off button), the next time the pump cuts...
  2. T

    Stay Rite Max E Therm 400 E 01 error code

    Second update: James, I fired it up yest and it has run correctly last nite and today..... no further E01 codes. Any chance the board took some time to reset and clear the code? I replaced an o2 sensor on my truck and it took a few days before the check engine life went off? I will hold on...
  3. T

    Stay Rite Max E Therm 400 E 01 error code

    Update: I turned on the heater this afternoon.... Startup seemed normal. Blower came on and igniter fires up.... readout read 62 or so which is likely accurate.... then I set temp to 80 which seemed to hold ...... Got home a few hours later.... blower and burner still running.... but readout...
  4. T

    Stay Rite Max E Therm 400 E 01 error code

    Yes, I reinstalled the old one and it did the same thing.... I have triple checked the connections. Right before the E01 code pops up I do hear a click. Thanks for the help!
  5. T

    Stay Rite Max E Therm 400 E 01 error code

    Hi All, Thank you in advance for your help. In the fall we moved into a house with a 2016 installed Sta Rite max E therm 400 gas heater. It worked fine initially, but the would shut down intermittently and the service heater lite would come on. Turing power of and back on would usually get it...