Search results

  1. T

    Pentair LA MS05 failure

    Forgot the pics.
  2. FE6F2B80-63E5-429D-97E4-F63DEDD318E8.jpeg

    FE6F2B80-63E5-429D-97E4-F63DEDD318E8.jpeg

  3. B0F9BB5E-887F-4B85-8620-EDFA9B3EAD3C.jpeg

    B0F9BB5E-887F-4B85-8620-EDFA9B3EAD3C.jpeg

  4. E1B9F9A6-C364-4192-9A05-53CCFDE6665B.jpeg

    E1B9F9A6-C364-4192-9A05-53CCFDE6665B.jpeg

  5. T

    Pentair LA MS05 failure

    Hi Guys, I appreciate all the help you’ve graciously given. I pulled my Pentair LA MS05 hoping to replace a bad bearing. (It was running very loud) Upon disassembly, which was a little challenging with no YouTube’s to go on, I found significant the shaft turn to be very tight. Then the shaft...
  6. T

    Pentair LA MS05 booster pump bearing question

    I suppose I can pull the bearings and check the sizes?
  7. T

    Pentair LA MS05 booster pump bearing question

    Pentair gave me the seal part number , but said they don’t make the motor (even though it carrier their decal) so couldn’t give me the bearing size or part number. Advice?
  8. T

    Pentair LA MS05 booster pump bearing question

    Hi Guys, I have a pentair booster running a Polaris in a 28 ft fiberglass pool. This was a new build <2 years ago..... Suddenly, the booster motor became very loud. It still drives the Polaris easily. I’m fairly handy and think I can replace the bearings if that is what it ends up being...
  9. 956679E8-6755-41C4-A5B4-0540C481CCA8.jpeg

    956679E8-6755-41C4-A5B4-0540C481CCA8.jpeg

  10. T

    Stay Rite Max E Therm 400 E 01 error code

    Quick Follow Up: As mentioned above, after changing thermister and letting the pool pump power up and cycle a few times, the heater started working properly. However, now, it will switch modes from pool to spa on its own. Also, if I turn it off, (heater off button), the next time the pump cuts...
  11. T

    Stay Rite Max E Therm 400 E 01 error code

    Second update: James, I fired it up yest and it has run correctly last nite and today..... no further E01 codes. Any chance the board took some time to reset and clear the code? I replaced an o2 sensor on my truck and it took a few days before the check engine life went off? I will hold on...
  12. T

    Stay Rite Max E Therm 400 E 01 error code

    Update: I turned on the heater this afternoon.... Startup seemed normal. Blower came on and igniter fires up.... readout read 62 or so which is likely accurate.... then I set temp to 80 which seemed to hold ...... Got home a few hours later.... blower and burner still running.... but readout...
  13. T

    Stay Rite Max E Therm 400 E 01 error code

    Yes, I reinstalled the old one and it did the same thing.... I have triple checked the connections. Right before the E01 code pops up I do hear a click. Thanks for the help!
  14. T

    Stay Rite Max E Therm 400 E 01 error code

    Hi All, Thank you in advance for your help. In the fall we moved into a house with a 2016 installed Sta Rite max E therm 400 gas heater. It worked fine initially, but the would shut down intermittently and the service heater lite would come on. Turing power of and back on would usually get it...