  1. Stenner Tech Support

    Stenner pump problem?

    Depending on the model there will be a few troubleshooting steps we could try. For the classic series you really want to make sure that your rollers are fully expanded. If it is an Econ - there is a latch behind the pump head we need to make sure is fully secured. For anyone interested, I have...
  2. Stenner Tech Support

    Stenner pump fitting material

    If you are using 1/4" tubing, we suggest the UCAK100 (pk of 10 connecting nuts) and the UCAK200 (pk of 10 ferrules). If you need further assistance, please don't hesitate to contact us here.
  3. Stenner Tech Support

    Stenner liquid chlorine pump - How to choose and install

    We are glad you are satisfied with our pump.
  4. Stenner Tech Support

    Chlorine injection location

    The ECON-T is rated for indoor and outdoor use. Remember to change the pump tube at least once/year. We hope this helps.
  5. Stenner Tech Support

    Chlorine injection location

    That is a very nice install. Let us know if we can be of any assistance.
  6. Stenner Tech Support

    Chlorine injection location

    Thank you for the kind words.
  7. Stenner Tech Support

    Chlorine injection location

    We are attaching the Basic Service Manual which may help later on.
  8. Stenner Tech Support

    Sizing a Stenner Peristaltic pump for liquid chlorine.

    We would suggest the 45M3 as the psi on the return side is usually around 25 psi and a check valve is not needed. We hope this may help.
  9. Stenner Tech Support

    New stenner econ T install

    Yes, it is a 1/2" T the injection fitting is screwed into. If you have further questions, please don't hesitate to email: [email protected]
  10. Stenner Tech Support

    Stenner Econ T?

    Very nice install!
  11. Stenner Tech Support

    Stenner pump

    If you will contact us, we can assist. [email protected]
  12. Stenner Tech Support

    For Sale: Stenner 85MPHP17 Pumps

    The coil (MP6J226) and power cord (MP6B020) would need to be replaced. The part numbers listed are for 220V. Attached is the Basic Service Manual.
  13. Stenner Tech Support

    TWO Stenner Pumps pulling acid from ONE Tank

    We do not suggest using a 'Y' as there is a chance of leaking at the connection. In regards to using the 3/8" tubing, the 1/4" is fine as the pump is a positive displacement pump and increasing the tubing size does not affect the output, unless a viscous solution. I hope this might help.