    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    I went straight home and checked the solder point that was pictured and described on this forum and sure enough, mine was burnt out. I was able to re-solder the burnt point and started the system back up. The delay counted down and bam, it worked perfectly! I couldn't have done this without all...
  2. IMG_0948.jpg

    IMG_0948.jpg

  3. S

    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    I'm new here but I too have the same issue with my salt system,,,High Salt / Amps. Would the burnt solder point be the problem if I'm still reading High amps on my unit? I can confirm my salt level is 3100 when I check it under diagnostics and run the instant salt / amp test.