Recent content by siberian

  1. S

    Raypak Versa 405B thermostat wiring diagram?

    I think I have the thermostat board bypassed and it works great. Good thing, those replacement boards are like $500.. Attached is a picture of what I did. The now bypassed thermostat board is in the top left. 1) Attached transformer 24V directly to 24V on ignition box 2) Attached thermostat...
  2. 2023-08-19_09-58-15.png

    2023-08-19_09-58-15.png

  3. S

    Raypak Versa 405B thermostat wiring diagram?

    Found the diagram.. Thanks TroubleFree Pool. Need to search for 5m longer before posting. That said, any tips on just bypassing this? Can I come out of my pressure switch, through the hi-limits, and drop to ignition ground? That would bypass the board entirely, but keep the safeties in place...
  4. S

    Raypak Versa 405B thermostat wiring diagram?

    My system is still running this ancient heater from 1987. Physically, the thing is bulletproof, however, we recently had a power fluctuation (main panel lost a leg and the heater system is 240) and it stopped switching on. I've debugged each component and done some maintenance. Replaced the...
  5. IMG_6605.jpg

    IMG_6605.jpg

  6. IMG_6606.jpg

    IMG_6606.jpg

  7. IMG_6566.jpg

    IMG_6566.jpg

  8. S

    Pentair Intellitouch Airswitch

    Signature updated, sorry about that. I recently upgraded my Compool to Intellitouch. The air switch currently switches 110V, it was used for the old pump so I will need a new one for sure. Thanks for the diagram, that makes a ton of sense, I had not thought about the IS4 connection, very cool...
  9. S

    Pentair Intellitouch Airswitch

    Just upgraded my Compool to Intellitouch and it went great but now I need to sort out my air switch. Previously the air switch in the spa directly controlled an old dumb pump that ran at a single speed. I replaced my spa pump with an Intelliflow VSF which means it is controlled over RS-485...
  10. S

    Spa pump backwashes when primary pump is off

    I think its time to do this, making my order now. Many dumb questions coming in a week or two, tx for all the help!
  11. IMG_5504.jpg

    IMG_5504.jpg

  12. S

    Spa pump backwashes when primary pump is off

    Thanks for this, it matches a lot of what I had in my head. 1. That was my initial thinking, I just was not sure if it was accepted practice or not. Sounds like it is.. But I think its probably better to just update my automation. There is a lot to be said for fixing all my problems at once...
  13. IMG_5502.jpg

    IMG_5502.jpg

  14. IMG_5503.jpg

    IMG_5503.jpg

  15. IMG_5505.jpg

    IMG_5505.jpg