    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    I have not blown a fuse since Hayward sent me the new OmniLogic Transformer. My system was blowing fuses every week. If you have an older Prologic or anything but OmniLogic Transformer they will blow. Hayward was very good and covered it under warranty.
  2. Chlor1.jpeg

    Chlor1.jpeg

  3. Sgt1411

    Issues with Hayward TCELL940

    Looking for some guidance I'm having a similar issues where the T15 (940) installed January 2023 is now providing very high Average Salt readings. Last week it showed 13,000PPM for Average and 2700PPM for Instant This week it was 8600PPM and 2500PPM for Instant First thought was dirty cell so...
  4. Chlor1.jpeg

    Chlor1.jpeg

  5. Chlor2.jpeg

    Chlor2.jpeg

  6. Sgt1411

    Omni PL Upgrade Kit Hayward Automation

    I don't know the answer to that as I have never had AquaLogic controls so I don't want to give you bad info. I would call the Hayward Tech Support line and speak to one the reps. Remember to push #2 when the automated phone support line asks are you a consumer push #1 or a pool professional...
  7. Sgt1411

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    I got on the phone again with Hayward Tech Support, took pictures of my old ProLogic Transformer inside the newly upgraded OmniPL box and the techs sent it to Hayward Engineering. After about a week they came back and said to change the Transformer from the old ProLogic original to the newer...
  8. Sgt1411

    Omni PL Upgrade Kit Hayward Automation

    Update: Three days now WTHOUT any fuses blowing on the board.........very happy as I was replacing fuses multiple times a week. Guys with fuses blowing just be aware of the Transformer issue with older ProLogic Transformers.
  9. Sgt1411

    Omni PL Upgrade Kit Hayward Automation

    Installed the new OmniLogic Transformer that Hayward shipped and so far no 20AMP fuse blowing. Fingers crossed it was the old ProLogic transformer that caused the issues.....Updates to follow.
  10. Sgt1411

    Omni PL Upgrade Kit Hayward Automation

    Just for reference I am currently deaing with Hayward Engineering on the issue of my 20AMP OmniPL PCB blowing. They believe its to do with my old ProLogic Transformer. They are shipping me a replacement and the part number is HLX-TRNSFMR It is apparently designed for the OmniPL PCB I tried to...
  11. Sgt1411

    t-cell voltage sensor short chlorinator 1

    Here is OmniPL Board and Transformer. Hayward had issues with the bubbles on the yellow wires
  12. Copy of IMG_6333.jpeg

    Copy of IMG_6333.jpeg

  13. Sgt1411

    t-cell voltage sensor short chlorinator 1

    Just an update, I received an email from Hayward Tech Support stating that they will be sending me a new transformer to help resolve the issue. The transformer is the old one from my ProLogic set up so I wonder if they are starting to see issues with this kit and the older transformers. The new...
  14. Sgt1411

    t-cell voltage sensor short chlorinator 1

    Still having the issues with blown fuses. Took my water sample to Leslies yesterday and their system read Salt level at 3471PPM......within a few hours the 20AMP fuse blew again. Sent everything to Hayward Tech Support, they escalated it to Engineering and they asked for pictures of my wiring...