Recent content by scottTX

  1. S

    Jandy JXI 400 Won't stay lit

    Problem solved. The heater has a secondary propane regulator on it, the vent (tubing) runs away from the equipment as it should. The vent pvc pipe had water in it which impacted the regulator. Drained water out of pipe and runs like it should.
  2. S

    Jandy JXI 400 Won't stay lit

    Hello all, Have a Jandy JXI 400 that won't stay lit. I did have to replace the Fenwal Ignition controller, after going through the troubleshooting steps in the Jandy book. Replaced with the exact same model. Now heater powers on, blower turns on, normal time delay then ignitor starts to glow...
  3. S

    SWG Error 120/121 but voltages all good with new SWG

    James-had to get a meter to read DC AMPs. Interesting results. I read 5.5 amps with it and still error 120, note this is with the new salt cell still installed. I also decided to get a new power board, figured just in case. Installed a new power interface board (R0467600). Measured 4.24...
  4. S

    SWG Error 120/121 but voltages all good with new SWG

    Thanks James. What is the DC AMP range I will need to measure? Looking on line for a clamp type and appears most only go as low as 40amp. Its the something else that's I'm worried about. I'll re-measure salinity during the week.
  5. S

    SWG Error 120/121 but voltages all good with new SWG

    Will do in the dc amps. Would be curious, if all the DC voltages are correct off the board why would the amperage be off? Here are some pics, thanks again!
  6. IMG_0365.jpg

    IMG_0365.jpg

  7. IMG_0372.jpg

    IMG_0372.jpg

  8. IMG_0371.jpg

    IMG_0371.jpg

  9. S

    SWG Error 120/121 but voltages all good with new SWG

    I'll have to get one that goes over the line. Here the pci
  10. PWS.jpg

    PWS.jpg

  11. S

    SWG Error 120/121 but voltages all good with new SWG

    Unable to do an amp test Yes replaced the cord Have two transformers small on the right side of the box R0466400 Aqualink Transformer Tu62132f0 The larger one is a Kenine KEA114UL-75V600-PT but I can seem to find it anywhere on line to tell what the part number is on the label it has...
  12. Aqua PWS.JPG

    Aqua PWS.JPG

  13. S

    SWG Error 120/121 but voltages all good with new SWG

    Yes new PLC 1400. Model received 1400, 3cell, 3 Prongs, DC voltage on both outside prongs is reading 30VDC. Salt level is reading 3.2 on the box as well as independent.
  14. S

    SWG Error 120/121 but voltages all good with new SWG

    Hello all, I have errors 120/121 showing up on my display. Challenge is that is after replacing the PLC 1400. I have checked each TP on the power board, all the DC voltages are spot on as well as the AC voltage TPs. The DC voltage reading at the Salt cell pulling the DC power cord up a...