Recent content by satpoolguy

  1. S

    leaking FNS Plus

    Agreed...but still weird the leak moves with the band. It irks me that I don't understand why, but I will get over it eventually :)
  2. S

    leaking FNS Plus

    You would think that. However, I am not sure that was the case. I ended up ordering an entire new filter. Between the cost of the clamp, my manifold being cracked and needing replacement soon, my filter grids probably needing replacement soon, and the uncertainty of what was causing the leak...
  3. S

    leaking FNS Plus

    It looks like the clamp is $160...I'd hate to throw that money away if it is unlikely to solve the problem. I agree there isn't much to go wrong on the clamp. Hopefully some other people will have thoughts.
  4. S

    leaking FNS Plus

    It is in a pretty sunny spot. You seem to be implying that you think it is the vessel itself and not the clamp. Was that your intent?
  5. S

    leaking FNS Plus

    I have an FNS Plus 48, installed in March 2013. Recently, it developed a leak where, or very near to, where the top and bottom meet. I am not sure how to best proceed and am hoping for insight. I've replaced the gasket (lubing it liberally), and it still leaks. I've inspected the band clamp and...
  6. S

    correct gasket for FNS Plus tank

    Thanks for all the discussion. It sounds like I need the round o-ring, so the one I have (trapezoidal) won't work. As for the cause of the leak, I do believe that I have the band properly tightened. I've been maintaining this filter since it was installed, so I've opened it and reassembled it...
  7. S

    correct gasket for FNS Plus tank

    Thanks for the replies so far. I think you can probably see why I'm confused -- we already have conflicting info on this thread! My filter was installed in 2005. It is definitely an FNS Plus model, the 48 to be specific. I can get pictures of the filter and label later. I "hope" I need a new...
  8. S

    correct gasket for FNS Plus tank

    I have found conflicting info on the web, so I am hoping someone here knows for sure -- should the gasket that seals between the top and the bottom of the filter tank on a Pentair FNS Plus be trapezoidal shaped, or round? I've found people selling supposedly the same Pentair part number, with...
  9. S

    strange possible suction-side leak

    So I think the issue is that even after I let a fair amount of water flow from the spa drain to the pump (i.e., pump lid removed, just letting water flow out), there was still quite a bit of air in the piping. I did this again, and after a steady stream of water, a bunch of air came out. I...
  10. S

    strange possible suction-side leak

    I ran into a weird situation I'm hoping for some help on. This morning I turned my pool on to spa mode and ignored it for about 20 minutes. When I returned, the spa was completely empty and the pump was running dry. I then noticed that the return valve was still set to split the return water...
  11. S

    AquaRite doesn't get power unless I push on control panel

    I removed and replaced it, and so far it seems to be working OK. I will continue to monitor it. Thanks!
  12. S

    replacing flange on Pentair Whisperflo

    I understand, but I assume the flange will only be about $70 whereas replacing the near-new motor would be > $400. It seems the flanges are sold separately, but I am not sure which one I need.
  13. S

    AquaRite doesn't get power unless I push on control panel

    I came home from vacation to find an algae infested pool. It turns out my SWG wasn't powering up (no lights on the display). If I push on the protective panel inside the box, it powers on and seems to work just fine. I removed the panel assuming I'd find an obviously lose connector or something...
  14. S

    replacing flange on Pentair Whisperflo

    mas, thanks for the link, but that doesn't show replacement of the flange on the motor. I'm good with replacing the seal plate, it is the flange on the motor itself that is giving me trouble.
  15. S

    replacing flange on Pentair Whisperflo

    I have a Whisperflo pump that needs to have the flange replaced as it (and the seal plate) is damaged. Based on a Pentair exploded parts diagram, I ordered part SAW-49, which is also known as 601400. However, this is apparently not the right part. While the dimensions where it meets the flange...