Recent content by SandBaggins

  1. SandBaggins

    Swapped Out Jandy Aquapure Board Causing Permanent "EC" Code - SOLVED

    After I moved the jumper to POS-1, the issue was resolved and chlorine is now being produced!
  2. SandBaggins

    Swapped Out Jandy Aquapure Board Causing Permanent "EC" Code - SOLVED

    I was laying in bed and couldn’t sleep thinking about this problem. So I decided to skim the manual to see if there was anything I missed. I discovered that there is a jumper that if in the wrong position, could produce exactly what I’m experiencing. The jumper should not be in this position by...
  3. IMG_4884.jpeg

    IMG_4884.jpeg

  4. SandBaggins

    Swapped Out Jandy Aquapure Board Causing Permanent "EC" Code - SOLVED

    Hello, My SWG stopped producing chlorine a couple months back. Pool was balanced, flow on, cell on, no error codes. My PLC1400 is a year old and clear of any buildup (I cleaned it anyway for good measure). My pool passed the overnight test without losing any Free Chlorine. Tested voltage at the...
  5. IMG_4845.jpg

    IMG_4845.jpg

  6. IMG_4844.jpg

    IMG_4844.jpg

  7. IMG_4857.jpg

    IMG_4857.jpg

  8. IMG_4874.jpg

    IMG_4874.jpg

  9. IMG_4873.jpg

    IMG_4873.jpg

  10. IMG_4869.jpg

    IMG_4869.jpg

  11. IMG_4860.jpg

    IMG_4860.jpg

  12. IMG_4859.jpg

    IMG_4859.jpg

  13. SandBaggins

    Jandy XLi Heater Won't Turn On With TSTAT Enabled ***UPDATE - FIXED***

    After inspecting the wiring, everything looked fine. The cable jacket was intact from end to end and the wires had not come undone. The cable itself had two unused wires, so I decided to try using those. Everything worked great using the two previously unused wires! Fairly simple fix if you know...
  14. New Heater Wiring.jpeg

    New Heater Wiring.jpeg

  15. New Panel Wiring.jpeg

    New Panel Wiring.jpeg