    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    So I did some more testing of the new heads. If I set the variable pool pump to 3450 RPM, I can indeed achieve 18 psi at the Valve and get the Heads in the SPA working correctly. Another option is to plug a single of the 6 Heads in the SPA. Then I can get it to operate correctly with 2900 RPM...
  2. R

    Are Pentair Pool lights ever going to come down in price again?

    It does, but seems more like a supply issue.
  3. R

    Are Pentair Pool lights ever going to come down in price again?

    I bought Pentair 640121 IntelliBrite 5G Color Underwater LED Spa Light, 120 Volt, 50 Foot Cord 4 years ago for $350 and now they are like $750. Any chance they will come down again or is this just the new price?
  4. R

    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    Thank you. I’ll keep the thread updated when I get a chance to test some more
  5. R

    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    One thing I haven’t really experimented with is increasing the speed of my Pool Pump. It was capped at 2900rpm, but can go up to 3450. I thought it was capped at 2900 for a reason to not put too much strain on my equipment, but not positive that’s the case. I installed a vacuum and pressure...
  6. R

    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    I still have the old heads, so I’ll probably try and put them back in the SPA to see what happens. I will be a couple of days before I can troubleshoot. The Gamma 2s for some reason have a lot of water escaping when not fully extended. Not through the intended hole, but everywhere else. Yes...
  7. R

    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    Now you mention it, I do remember that. Can’t help but wonder if the original design was different. It seems backwards now the way they did it. It would actually make more sense if they had hooked it up in the order it’s placed. So first the IFCS so you can run that completely isolated from...
  8. R

    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    P Probably need to rethink the original design completely to solve my problem. Even without supplying any of the water features and bypassing the Heater I have a Bypass Valve, 10x90s and 1x45 Between the filter and the Manifold. I'm loosing 10 PSI+ in the process.
  9. IMG_3174.png

    IMG_3174.png

  10. R

    Switched from IFCS Original MagnaFlow to A&A Gamma Series 2 and seeing lower pressure at the Valve

    Had my pool resurfaced and in the process decided to switch all my pop-ups from the Original MagnaFlow to A&A Gamma Series 2 pop-ups. Afterwards I'm seeing much lower max pressure at the Valve. So before running my Pump at 2900 RPM I would typically see around 20PSI at the Filter newly...
  11. R

    Stenner liquid chlorine pump - How to choose and install

    Excellent!! Never knew such a thing existed. That will be very helpful!
  12. R

    Stenner liquid chlorine pump - How to choose and install

    That may be the reason. I live in PHX, so I know everything about hot pool water :) I only inject once daily and I do it during the cleaning cycle, so lots of flow.
  13. R

    Stenner liquid chlorine pump - How to choose and install

    What flow indicator do you use? I’ll add my 2 cents. I replace my duckbill and the pump tubing every year and clean out the injection point and the “weighted”suction in the tank at the same time. My T is vertical and I use the 0.51 GPH tube in my EconT and can normally go a year without issues...
  14. R

    Stenner liquid chlorine pump - How to choose and install