Recent content by rich6429

  1. R

    Should FC ever be added after adding Polyquat 60 when closing the pool?

    so...can someone check if my steps below is the right steps to take? SLAM pool let pump run for 24 hrs drain pool after 24 hrs Close pool add polyquat roughly after a few days depending on FC. only reason I have 24 hrs...is because I dont have a lot of time between now and closing the pool. I...
  2. R

    Where to connect Intellivalve?

    Thanks. All of that is really helpful. last question just for my own clarity...there is no way to have one pre-set stop? the 2 stops are now 0 and 24...but can it be 0 and 18?
  3. R

    Where to connect Intellivalve?

    ok thanks... so I have setup the home stop "0" and another stop. I have been playing around INtellicenter, but cant seem to find a way to control it using the Intellicenter. CAn you assist?
  4. R

    Where to connect Intellivalve?

    Thanks. Does that mean I would connect the 3 pin to Valve A or B? If so, what about the green/yellow wires? Also, although the “on/off analogy” is fine as you explained, I thought I was able to do a 75/25 split if I wanted to with the Intellivalve.
  5. R

    Where to connect Intellivalve?

    I just got an Intellivalve that will control my pool returns (which will be primarily on), and if I have to turn on my water feature. So it is going on a 3-way From a wiring standpoint, do I just put the 3 pin in either the Return or Intake? I also see other wires (yellow and green) in the...
  6. R

    Intellivalve when winterizing

    Wondering what you all do when winterizing your equipment. Do you leave your Intellivalve hooked up and wired in? Or do you take it out and disconnect from IntelliCenter during the winter period? I keep everything out with the exception of my salt cell.
  7. R

    Heater fires up for a few minutes and shuts off

    Apparently, according to the technician that serviced the heater...it is also a common issue.
  8. R

    Heater fires up for a few minutes and shuts off

    To close the loop on this topic...issue was the stack flue sensor. I did disconnect and tested resistance. It wasnt registering any in my meter. But the heater continued to worked intermittently, so continued to use it. I just had to power off and power on to restart. I ended up calling...
  9. R

    Heater fires up for a few minutes and shuts off

    I did display the SFS temp…and it was going from the 100’s to around 350…then would all of a sudden change to 40 and stay there. And then it turns off.
  10. R

    Heater fires up for a few minutes and shuts off

    When it stops running, I turn the heater off. When turning on, this is what the panel says (pic attached) quickly and disappears. Heater would fire and ignites. “Heating” light is also on. After a few mins, it shuts down.
  11. IMG_7789.jpeg

    IMG_7789.jpeg

  12. R

    Heater fires up for a few minutes and shuts off

    Looks clear to me.
  13. IMG_7788.jpeg

    IMG_7788.jpeg

  14. R

    Heater fires up for a few minutes and shuts off

    Pool temp stayed low so I had took a look at the heater (Pentair Mastertemp 200). I noticed it had E05 error, and automatically assumed it was the Stack Flue Sensor since it is what Google tells me :). HOwever, after powering off and then powering on the heater, I noticed that the panel showed...