Recent content by QDay

  1. Q

    2 speed pump, runs on hi only now

    Thanks, that was it. The low speed popped on when I changed the aux 2 setting in the config menu, the default setting was "off" I think.
  2. Q

    2 speed pump, runs on hi only now

    Gotcha, it's new (to me just bought the house), I'm still not sure what i have exactly. It's an aqua logic controller just like the ones in the SWG K1 relay thread, although my stuff has blue haven pools labeled all over it. I'll look at it closer and get more info and add a sig. After...
  3. Q

    2 speed pump, runs on hi only now

    Could it be an Aux 1 or Aux 2 problem? Set to "off". I am going to try that next, i don't know what the Aux are for but i think they are both off on the settings. I may have done that by accidentally restoring default settings.
  4. Q

    2 speed pump, runs on hi only now

    I fixed my SWG K1 relay solder issue this weekend thanks to the thread on here about it. Right after we put the panel back on, screwed it down, etc, i noticed that the pump would run on hi speed but not on low speed. With the timer having it on at low, it's off, change the timer so the hi...
  5. Q

    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    Re: Aqua Logic Salt Too High - Cholrinator Off High Salt/Amp I used 60/40 solder with a kit from amazon. Mine is fixed. Had to do it more than once, did not work the first few times. Then we cleaned all the old solder off and re-d-d it and it worked. Clean all the old off before you...
  6. Q

    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    Is that the before or after? Is the problem pin on the bottom right of the pic? Am I going to electrocute myself when I try this?