Recent content by nestler

  1. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Update: worked well after the change of the board the whole season.
  2. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    My system was close to 5 years old. So I did change the salt cell which made me feel good, but didn’t change the status and still got the error messages. I did buy a new mainboard which did fix the issues. Replacement was easy and has been working well for the last 2 months.
  3. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Hi, I did install a new salt cell and changed the fuses. Still get the same error message. What is next, the main board or theT-Cell PCB Board? It looks ok.
  4. T-Cell Board Omni.png

    T-Cell Board Omni.png

  5. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Thanks, just ordered one and will let you know.
  6. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Do you think it is the cell and not the board? Thought these error messages are triggered from the panel.
  7. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    OmniLogic: 3K18031-182412 t-Cell: 4E18206-203432
  8. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Not sure about the salinity. It shows on the omni
  9. IMG_4152.jpeg

    IMG_4152.jpeg

  10. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Not sure what you mean by opening. The fuses don’t seem to be blown when I change them.
  11. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    The plug is a little discolored, but not burned as I saw on other pictures. The board appears to be cosmetically ok. I did replace the fuses, but came back after a day. Seriously thinking about having to change the board.
  12. N

    Hayward Omnilogic Salt Cell Burned at motherboard

    Any update? Did you replace the board or T-Cell?
  13. N

    OmniLogic - T Cell current Sensor Short K1/k2 Relay stuck open

    Hi, I saw older threads but not sure there is a clear answer to my issue. I am receiving intermittent errors that the K1 and K2 relay are stuck open and the T-Cell current sensor is short. Error message goes away after a while, but returns. I changed the 4Amp fuse which did not get the permanent...