Recent content by Michelle E

  1. M

    No connection to easy touch from main filter pump

    I don't have an antenna it's hard wired to the Screen logic protocol adapter then works off my wi-fi. I'll get a picture tomorrow.
  2. M

    No connection to easy touch from main filter pump

    When I checked the red and black it was high can't remember exactly, but the yellow and green were 0. They were telling me so many things and this is all new stuff to me I can't remember exactly. I'm learning as I go. I can recheck tomorrow if that helps you and I won't need a new board.
  3. M

    No connection to easy touch from main filter pump

    Ogdento No the screen logic doesn't work at all. The way my ET buttons are set up is Pump, 1 is cleaner, 2 Waterfall, 3 pool high, 4 Spa ,5 pool lights, 6 spa light, 7 Spillway. The LED lights above the numbers come on when pressed but the Pump, Spa, Pool high, and spillway do nothing but the...
  4. M

    No connection to easy touch from main filter pump

    Thanks for your quick replies. I spoke with pentair and they did some trouble shooting with me. The only thing on that comm cable is the main vs pump. All the other pumps and lights...are all seperate. After checking the main ET board with a volt meter I'm being told it's the board that is bad...
  5. M

    No connection to easy touch from main filter pump

    I'm needed help with a connection issue. I have a Pentair intelliflo vs pump and it was connected to the easy touch. I was able to control the pool and features through a hard wired screen logic. Now I can't control the pump with easy touch or screen logic. I changed the communication cable that...