Recent content by matj6876

  1. matj6876

    CH "Jumped" to 700+ over the winter.

    Retested using the "fading endpoint" method and got a very clear CH reading of 675. I suspect my testing methodology has become lax here over time. My CH level has crept up and I have not really noticed. I will partially drain and refill ... when it gets a little warmer! Thanks for the help.
  2. matj6876

    CH "Jumped" to 700+ over the winter.

    My initial (fearful) reaction was that I've done something so terrible it's leached out of the plaster. But I don't know if that's even a thing really... so you are right; I have no explanation for where the calcium has come from - that's why it's surprising to me. It's a fair call on the...
  3. matj6876

    CH "Jumped" to 700+ over the winter.

    Sorry - I should have mentioned that. Very little fill water. Some, but not much - we have had enough rain to keep things topped up. No Cal-Hypo. The only chemicals I have added in the last 6 months have been Bleach and Muriatic Acid
  4. matj6876

    CH "Jumped" to 700+ over the winter.

    Hi Folks I've been running the TFP way for a long time. I don't post here much because I don't have a complicated set up and, I guess, I have been pretty lucky too! ;) For the last several years, over the winter, at the point the water temp drops into the mid 50s F, I take out the SWCG, do one...
  5. matj6876

    IntelliFlo <> EasyTouch issue - The Return!

    Hi Brian - Longest I've waited is 15 mins. Most of the time right now i'm giving it about 2 mins.
  6. matj6876

    IntelliFlo <> EasyTouch issue - The Return!

    OK - this one is officially on the back burner. The issue is so exactly repeatable that it's possible for me to do whatever I need to do to keep limping along, provided the thing keeps running to a schedule. I think I also have flow rate issues but I need to get my filter cleaned before I jump...
  7. matj6876

    IntelliFlo <> EasyTouch issue - The Return!

    Hi All back home and back on the case of this one. Jim - this is an easy one to answer: No, the pump does not start but as expected the pump's display says: "Pump Address 1 DISPLAY Not Active!" Correspondingly if the pump is started up again, while in service mode, then I make the switch to...
  8. matj6876

    IntelliFlo <> EasyTouch issue - The Return!

    Hi Jim (and anyone else who wants in on this puzzle!) Assume nothing when it comes to my pool knowledge! It's self taught and has more holes than Swiss cheese. In this instance though.. Yes, pushing the mode button twice AUTO > SERVICE > TIMEOUT > AUTO. Yes, when in auto pump looks like...
  9. SL9.jpg

    SL9.jpg

  10. SL8.jpg

    SL8.jpg

  11. matj6876

    IntelliFlo <> EasyTouch issue - The Return!

    Re: IntelliFlo &lt;&gt; EasyTouch issue - The Return! Thanks! That was not something I had checked! Sadly - No delays or alerts.
  12. SL7.jpg

    SL7.jpg

  13. matj6876

    IntelliFlo <> EasyTouch issue - The Return!

    Hi both To detour on wiring for a moment. Yes, it's a mess... a beautiful rainbow of a mess! It's not one of my creation, and i don't think it's go anything to do with my problem here, but I have poked around enough to be able to explain it. Its a 240V system so there are 2 x 120V feeds that...
  14. SL6.jpg

    SL6.jpg

  15. wiring2.jpg

    wiring2.jpg