Recent content by loudandslow

  1. L

    IC40 flow light is red

    I think my symptoms are similar. The power center board is outputting 42V DC to the cell. The flow switch is new and works - I measure 0V on cell side of the wiring when pump is on, 5V when pump is off (flow light red) Over last week I have noticed the flow light turning green but now it seems...
  2. L

    IC40 Cell Light problem

    Figured I'll follow-up - cut off the cell temp sensor, measured nothing near matching what a 10k thermistor should show. Replaced and now the cell temp is correct and it's back to producing chlorine. Thanks!
  3. L

    IC40 Cell Light problem

    Basically to keep in mind that it's downstream from the heater.
  4. Screenshot_20220112-215916_Pentair Home.jpg

    Screenshot_20220112-215916_Pentair Home.jpg

  5. L

    IC40 Cell Light problem

    I chose to plumb the power to the cell through the same relay as the pump to be really certain that a bad flow switch doesn't grenade anything. Plus seemed like possible energy saving and i didn't come up with a downside. So in that screenshot it's really off. It shows the same thing when pump...
  6. Screenshot_20220112-215544_Pentair Home.jpg

    Screenshot_20220112-215544_Pentair Home.jpg

  7. Screenshot_20220112-215552_Pentair Home.jpg

    Screenshot_20220112-215552_Pentair Home.jpg

  8. Screenshot_20220112-215615_Pentair Home.jpg

    Screenshot_20220112-215615_Pentair Home.jpg

  9. L

    IC40 Cell Light problem

    They are separate values. One probe i plumbed directly to the intelliconnect (for heater control) and the second reading over comms from the cell. When the temps were higher the 2 values matched within a few degrees. You can see from the screenshots (pump off for 5hrs now) I'm with you on...
  10. Screenshot_20220112-211105_Pentair Home.jpg

    Screenshot_20220112-211105_Pentair Home.jpg

  11. Screenshot_20220112-211124_Pentair Home.jpg

    Screenshot_20220112-211124_Pentair Home.jpg

  12. L

    IC40 Cell Light problem

    I just installed IC40 about 3 weeks ago and initially it worked as expected (temps matched, salt level matched). The temps dropped, freeze protection is coming on every night over the last week. Water temp is ~52D. Salt tested with a kit at 3500ppm. The cell turns off - makes sense with the...