Recent content by juancapool

  1. J

    Pentair 1.5 hp pump will not start

    haha I have better things to do! On to finding a replacement motor or $1100 for a VST pump (ouch). Thanks for the assistance JamesW, it's appreciated.
  2. J

    Pentair 1.5 hp pump will not start

    Ground to L1: keep going up 36 Mohms Groun to L2: settled at 3.7 K ohms
  3. J

    Pentair 1.5 hp pump will not start

    Good point. One thing is that the motor shaft is loose both fwd and backwards so there's nothing physical impeding rotation.
  4. J

    Pentair 1.5 hp pump will not start

    Yeah. 120v to each leg and 240 across both. The timer is putting out power.
  5. J

    Pentair 1.5 hp pump will not start

    I believe I did and then took the reading afterwards. I got a 15 from a 30micro capacitor.
  6. J

    Pentair 1.5 hp pump will not start

    The pump is from 2013. 9 years old.
  7. J

    Pentair 1.5 hp pump will not start

    The old capacitor gave me a reading of 15 microfarads. I replaced it and installed a new one (30 microfarads ) and the pump would not start.
  8. J

    Pentair 1.5 hp pump will not start

    And no sound at all. As if it was not connected to power.
  9. J

    Pentair 1.5 hp pump will not start

    Hi JamesW, I disconnected all the cables and the reading in 0.L which is an open circuit, infiniti I believe.
  10. read.jpg

    read.jpg

  11. J

    Pentair 1.5 hp pump will not start

    Hi, new to this forum and looking for some help with pool pump that will not start. It is a Pentair 1.5 hp pump (Model SF-N1-1-1/@A/340039). I did the following: Replaced the 30microfarad capacitor with a new one Checked the impeller and it is loose, it moves freely. Each motor leg has 120v...
  12. PXL_20220902_204735502.jpg

    PXL_20220902_204735502.jpg

  13. PXL_20220902_204750306.jpg

    PXL_20220902_204750306.jpg