Recent content by JohnKDavis

  1. J

    IntelliFlo VSF program not running correctly.

    Thanks, Jim! I can't think of any reason for him doing so either; I guess that's why it never occurred to me that he was behind all this until he called yesterday to tell me to stop resetting my pump. I'm disregarding his advice and now running the pump for 8 hours at 1700 rpm. John
  2. J

    Proper settings for a Pentair VSF Intelliflow pump in southern California to prevent algae?

    Thanks, guys! You've confirmed my understanding of the threads and pool school articles. It seems I need to ignore my chemical guy. (I use a pool guy only because my wife insists on it. Long story which has yet to reach its conclusion.) And thanks for such prompt responses. This is a great...
  3. J

    Proper settings for a Pentair VSF Intelliflow pump in southern California to prevent algae?

    I live in a hot, dry part of southern California where temperatures are often above 100 in the Summer. I have a Pentair VSF Intelliflow pump. My kidney-shaped pool is roughly 35 feet long, 15 feet wide at the widest, and six feet deep in one end. The guy who does a weekly chemical treatment...
  4. J

    IntelliFlo VSF program not running correctly.

    Thanks, Jim. Once the factory settings are back on, do I have to clear those programs too, or just go ahead and set my programs as I want them? Incidentally, yesterday I got some more information. The pool guy who does my chemical service has, apparently, been changing the settings on the...
  5. J

    IntelliFlo VSF program not running correctly.

    Hi Jim, Your Pentairese is far better than mine! I want program 1 to run from 7 am to 2 pm at 20 GPM or 1750 rpm (don't really care which), and program 2 to run from 2 pm to 4 pm at 3250/65 GPM (don't care which). I've repeatedly programmed them to those settings over and over, and watched a...
  6. J

    IntelliFlo VSF program not running correctly.

    Hi Mknauss and Jim, thanks for the help! I'll try that. I'm embarrassed to ask this, but I'm new to these pumps: how do I clear/delete a schedule? When I went through the program settings just now, I saw choices between scheduled/manual/egg timer for some of them, and other programs have a...
  7. J

    IntelliFlo VSF program not running correctly.

    I am posting a reply here because this thread is the closest to my problem that I was able to find in my search, and this is the only advice that might work for me. Nonetheless, let me run this past you guys... I have a Pentair Intelliflow VSF which I program using the keypad attached to the...