Recent content by issacsim

  1. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    Problem Solved !! Thank yo to James and everyone else !! Plumber tested the blew and tested lines, they were clean and no leaks. Next he checked the pressure coming from grid, which has dropped to 1 PSI. We called Gas company and they came in and changed the meter and regulator and a bunch of...
  2. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    Yes we do, it's the main for the backyard (BBQ and Pool) we shut it off whenever we close the pool for the season. It's fully open.
  3. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    Thanks, already called my gas contractor (the one who installed the line) will be here in tomorrow morning. I will post here once we find out the issue, so hopefully it will help someone else. Thanks for all your help !!
  4. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    I am guessing we found the issue? I am getting 6.17 when off, and -1.28 when calling for heat. What could cuase pressure to drop in a gas line? we installed this gas line about 6 years ago and was working fine until last season.
  5. 2020-06-04 16.44.20.jpg

    2020-06-04 16.44.20.jpg

  6. 2020-06-04 16.43.58.jpg

    2020-06-04 16.43.58.jpg

  7. 2020-06-04 16.44.20.jpg

    2020-06-04 16.44.20.jpg

    Gas on
  8. 2020-06-04 16.43.58.jpg

    2020-06-04 16.43.58.jpg

    Gas off
  9. Issac

    Issac

    Pool Stuff
  10. 2020-06-04 16.43.58.jpg

    2020-06-04 16.43.58.jpg

    Gas Pressure off
  11. 2020-06-04 16.44.20.jpg

    2020-06-04 16.44.20.jpg

    Gas Pressure on
  12. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    Thanks again James ! Ordered this Manometer, gas cut off valve is inches away, looks simple enough to try. Thank You!
  13. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    I played around with the new ground wire location and now I am getting solid 2.5 - 2.6, and within 10 seconds it starts dropping slowly and shuts off when reaches 0.3 - 0.4. I checked continuity of ground points earlier, didn't pay attention to ohms resistance, what number am looking for...
  14. I

    STA-RITE SR400HD Will not stay on. SOLVED !!

    Hi James, I tested the current between the FC +/- and it fluctuate between 0.50 and little over 2, mostly it stays below the 1.0. Is there a way to test if I did the extra ground correctly?