  1. G

    Black and Decker variable speed pump seal

    Thank you. My only issue is that it's $55 shipped for just a seal. Pretty sure that's more than OEM Hayward. Any idea if there are other generic more affordable optioms that will work? It doesn't sound like anyone has verified it yet.
  2. G

    Black and Decker variable speed pump seal

    I'm trying to figure out where and what seal to get now without spending an arm and a leg.
  3. G

    Black and Decker variable speed pump seal

    Did you or anyone else find out about this? I think I need a seal for my B&D 3hp already :/
  4. G

    Hayward Goldline Pro Logic Transformer smells like burning

    I will give that a test. We have been having very sunny 100+ days so I'm sure thats eating up quite a bit. I bumped it up to 25% now.
  5. G

    Hayward Goldline Pro Logic Transformer smells like burning

    I think it is 3E23005-700903 but that may be some other designator. Sorry for the delayed response. I did turn down the salt genration but Ive noticed my chlorine numbers are still pretty low.
  6. G

    Hayward Goldline Pro Logic Transformer smells like burning

    Genuine. Should it be negative or positive volts/amps or what does that do by pressing +
  7. G

    Hayward Goldline Pro Logic Transformer smells like burning

    First reading: -25.01V -6.50A 81degrees F 3400 PPM pressed + then read +24.84V +6.96A 81degrees F 3700 PPM Pressed + again -24.84V -6.86A 81degrees F 3700PPM Im not sure what you mean by the first 7 characters of the cell but it shows 942001E Rev K, T-CELL-15...
  8. G

    Hayward Goldline Pro Logic Transformer smells like burning

    Sorry for the delay in answering, its been a busy few weeks. I will try testing turning off the swg for a bit to see if I still feel the heat and the smell. Maybe I'm doing something wrong here but I thought I was shooting for 8 FC with cya near 70 with a salt water pool. Now I will admit...
  9. G

    Hayward Goldline Pro Logic Transformer smells like burning

    The original setup is I'm guessing about 10-15 years old. About a year ago I switched over to a salt cell, adding it to the Pro Logic pl-p-4. Perhaps it was bumping it up to 60% or maybe it's done it all along but the other day I was near the box and smelled an electronics burning smell coming...
  10. 20240613_231225.jpg

    20240613_231225.jpg

  11. G

    Wiring in black & decker vsp to pro logic with automation adapter

    I got it sorted. Not sure what setting I changed, but it seems to be working as intended now. Thanks to everyone for the help.
  12. G

    Wiring in black & decker vsp to pro logic with automation adapter

    Im about to pull my hair out at this point lol. The relay tested bad so I went ahead and ordered a new one. I installed it today and no luck. So I started diving deeper and when I set the Aux2 to filter low speed, theres a click when I engage low speed but the black thing does not pop up and...
  13. G

    Wiring in black & decker vsp to pro logic with automation adapter

    So I went back and forth with poolpartstogo and this was stated: Me: At high speed the filter pump relay solenoid black peg gets sucked in, no movement on the others, when I switch to low speed the filter pump relay pops out but the aux 2 relay does not move. Them: If the AUX2 relay isn't...
  14. G

    Wiring in black & decker vsp to pro logic with automation adapter

    Alright I got my third or fourth automation panel in today and as of right now, it's not restarting every minute. The new issue is that when I press to filter button on my Hayward pool control panel which is supposed to switch to low speed, it turns the pump off. I hear the relay click and if I...
  15. G

    Wiring in black & decker vsp to pro logic with automation adapter

    I really don't have a decent fix in the meantime. I'm using the standard panel right now waiting for a fix.