Recent content by Gmc9907

  1. G

    Skimmer suction issue - low and surging

    Help! when when I have the suction valve set to skimmer and main drain or skimmer only I get inconsistent suction and lots of air bubbles in the return. The water in the pump basket rises and falls and the pump does Not really prime. When I have the suction valve to main drain only everything...
  2. G

    Jandy LXi heater not working

    Thanks MKnauss
  3. G

    Jandy LXi heater not working

    Help!!! When I turn the heater on nothing happens and there are no lights on the heater user interface. I’ve followed the troubleshooting guide and used a multi meter to check voltages across the transformer, power interface board, and power distribution board. All have the correct voltages. I...
  4. G

    iAqualink cloud outage?

    Mine is not working. Red and yellow lights on the box are illuminated but no green light which is the WiFi light. Has anyone spoken with Jandy?
  5. G

    Jandy LXI Heater - Issue with Power

    Closing the loop for others who may have a similar issue in the future. Followed the troubleshooting guide for voltage and it lead me to the transformer. I replaced that and the burnt out power distribution board and I’m back in business. Thanks all for the replies.
  6. G

    Jandy LXI Heater - Issue with Power

    6-7 years old
  7. G

    Jandy LXI Heater - Issue with Power

    Thank you sir. Wiring looks good based on initial inspection. Will check voltage. Any other thoughts?
  8. G

    Jandy LXI Heater - Issue with Power

    Tried to heat the spa the other night and realized there was no power on the heater display (eventhough the rest of the pool equipment was working fine). Cut the power to everything and opened the heater panel and noticed burn marks on the power distribution board. Bought a replacement, hooked...
  9. G

    Jandy AquaPure 1400 “no flow” spa mode only

    All good there (I think). It’s set at 15% for the winter season and I up’ed it to 100% to try and figure out what is going on. When at 100% it just says “no flow” the whole time with no error codes.
  10. G

    Jandy AquaPure 1400 “no flow” spa mode only

    Thanks, JamesW. Answers: I do not have the small adaptor board with the calibration buttons. The buttons I have on the pcb include: h-temp, r-temp and salinity. The number on my board is 01220A15 and I am set to program A. Hopefully this helps. Thanks everyone.
  11. G

    Jandy AquaPure 1400 “no flow” spa mode only

    Hello i recently upgraded from the pda to iaqualink 2.0. As part of the upgrade I had to replace the control board (the part with the buttons to control pool functions manually). since the upgrade I’ve been getting the no flow reading on the control board screen while in SPA MODE only. The...
  12. G

    iAqualink 2.0 Upgrade - Connector Question

    How did this turn out? I have the same question.