Recent content by Farmer7185

  1. F

    Raypak Analog Heater not reaching set Temp

    Hi all! Looking for help on where to look at this problem with my Raypak Analog gas heater - model 106A. Heater will not warm the water above 84 degrees even with the thermostat turned all the way up. This has been going on for several weeks. I used to be able to warm the water to 90 degrees...
  2. F

    Raypak 106 Analog Heater - will not start

    Hi Mlange126. Turned out that my multimeter was defective and I did not need a transformer after all (now have a spare for futures)… My issue turned out to be the thermal cut-off fuse. I got the replacement on Amazon. Cheap fix, but hard to get to on this model to actually replace. If you...
  3. F

    Raypak 106 Analog Heater - will not start

    Yes. Pulled leads and checked. No 24v… ordered a transformer. Thanks!
  4. F

    Raypak 106 Analog Heater - will not start

    Limits and flow check ok (closed).
  5. F

    Raypak 106 Analog Heater - will not start

    Thanks. I have 120v coming into the transformer, and the on/off switch checks ok with an Ohm meter. No 24v at the ignition control or the temp control… simply the transformer is bad? Or, is there some other possible defect keeping the transformer from outputting the 24v?
  6. F

    Raypak 106 Analog Heater - will not start

    Heater working at end of last season. At startup this spring, on-off switch stuck in off position. Sprayed with WD-40 and switch freed up. However, the heater acts “dead”… no attempt to light after turning on and setting thermostat…. I can hear a click when turning on power switch and also...