Recent content by fabsroman

  1. F

    water guru

    Exactly what water parameters does the Guru measure? Is it just chlorine and PH, or does it test for more than just chlorine and ph? I am asking because I am thinking about getting it. Thanks
  2. F

    Pentair Intellichlor IC40 is not working - what are my options?

    Looked at the label and the manufacture date is 5/31/2011. Guess I should be ecstatic that it actually made it through last season. How it only has 6,000 hours on it is beyond me. Time to buy a new chlorine generator and it looks like I am going with the IC60 since I cannot find the IC40...
  3. F

    Pentair Intellichlor IC40 is not working - what are my options?

    I can get an IC60 for $959. Would this be a drop in replacement for the IC40, but with a longer useful life since I would need it to generate chlorine a lot less often than the IC40. The IC60 produces 2.0 pounds per day versus 1.4 pounds with the IC40? Since the useful life is supposed to be...
  4. F

    Pentair Intellichlor IC40 is not working - what are my options?

    We have been in the house for 18 months now and this will be our second season with the pool. The IC40 was working just fine up until yesterday. Had 7.0 fc yesterday. Yesterday, the "Cell" light was flashing, which translates to "Inspect Cell". I found some debris on the cell fins on the inlet...
  5. F

    Do I have an Ammonia problem?

    Yep, I had an ammonia issue when we opened up the pool. Poolgate helped me with opening the pool and figuring out my water parameters. Ammonia was above 8 ppm according to my aquarium test kit (highest it will measure since all the fish would be dead already) and dumping in 10 gallons of 10%...
  6. Attach125186_20200502_124501.jpg

    Attach125186_20200502_124501.jpg

  7. Attach125192_20200502_130934.jpg

    Attach125192_20200502_130934.jpg

  8. Pool Before and After 200427.jpg

    Pool Before and After 200427.jpg

  9. F

    Sodium Bicarbonate (Baking Soda) or Sodium Carbonate (Soda Ash) and other water parameters and additions needed

    Sorry for getting back to this so late. As Poolgate mentioned, this pool required 50 gallons of 10% pool chlorine to get rid of the ammonia issue. In the process, the ta and ph became what it is. I measured the ph with an aquarium test kit and that is how I was able to test down to 6.4. I added...
  10. F

    Sodium Bicarbonate (Baking Soda) or Sodium Carbonate (Soda Ash) and other water parameters and additions needed

    Got my SWG up and running yesterday. FC went from 3.0 yesterday morning to 7.0 today running the IC40 on high for 24 hours. CC went from 1.0 to 0.5 or less. Pool is around 37,000 gallons Today's tests resulted in: FC - 7.0 CC - 0.5 TA - 20 CYA - 20 but still have some in the skimmers and...
  11. F

    Algebraic equation for salt so I can work backwards and figure out the size of my pool.

    Thank you very much. Just bought 24 pounds of sodium bicarbonate yesterday. Thing is, I think I am going to end up using sodium carbonate (pot ash) right now because both my ph and alkalinity are low in the pool. Pretty sure I will have the "pleasure" of using the sodium bicarbonate at some...
  12. F

    Algebraic equation for salt so I can work backwards and figure out the size of my pool.

    I added 120 pounds of salt to my pool and raised the salt reading by 325ppm. I am trying to work backwards from this to get a better feeling for what my pool size is. The previous owner told me that it was 37,000 gallons and I am just trying to confirm this number. I have used the Pentair...
  13. F

    Can I put an electric heater on my pool? I ask because there might not be enough amps

    Breaker at the house for the subpanel is 50 amps and there are two 20 amp breakers in the subpanel (i.e., pool pump and booster pump) and two 10 amp breakers (i.e., lights and IC40). This does not shock me because no repairs done to this house were done well, much less to code. I have room in...
  14. F

    Can I put an electric heater on my pool? I ask because there might not be enough amps

    I have 50 amps running from the house to the Pentair Easy Touch panel by the pool. I am about to install an Intelliflo 3hp variable speed pump, which would most likely go on a 20 amp breaker at the pool panel. This is the same breaker powering the current 1.5hp single speed Pentair pump. Only...
  15. F

    Which pump for my pool?

    Thanks for that link. I was going to put PVC unions right before and after the pump. Those pump unions are what is on the current pump, so I will just order them too and use them on the new pump. Of course, that reminds me that I need to deal with the unions for the Pentair CCP420. Whoever...