Recent content by Elian

  1. E

    Too High CH Level 4 Months Post Resurfacing

    Outline your CH testing..... I'm pretty confident I'm testing it alright. Answers below: water sample size first I did it with 25mL then the next two I did with 10mL so as to conserve reagent drops for such high readings. I pulled new water samples for the second and third tests. how many...
  2. E

    Too High CH Level 4 Months Post Resurfacing

    Yes. There was silly, crazy amounts of white, cloudy, plaster dust in the water immediately after brushing for I'd say almost two months. Finally I got rid of it all where the pool is super clear now.
  3. E

    Too High CH Level 4 Months Post Resurfacing

    This is what I'm looking for some expert advice on :). One of the first things I considered was maybe the resurfacing plaster dust deposited something leading to this high level CH of my pool water. But I did some brief research and did not notice any mention of newly built or resurfaced pools...
  4. E

    Too High CH Level 4 Months Post Resurfacing

    100 ppm CH city fill water
  5. E

    Too High CH Level 4 Months Post Resurfacing

    Had pool resurfaced with a pebble finish on 11/1/2022 and builder did initial startup. I took over maint and chem balancing from the PB on 11/6/2022. Per TFP forum recommendations I followed NPC startup guidance processes. On 11/27/2022 started using a Taylor K2006-C test kit and tested CH to...
  6. E

    Sequestrant following Resurfacing: How Long?

    Question regarding how long I should apply Jack's Magic the Magenta Stuff sequestrant after an SWG pool resurfacing 30 day start-up period: SWG pool was resurfaced eight weeks ago with a Florida Stucco plaster pebble finish. A week following initial fill I paid the PC and they disappeared so...
  7. E

    For 13,200 Gallon Plaster Pool: CircuPool RJ-30 PLUS or RJ-45 PLUS?

    Thank you for sharing this. I now have the Pool Math app and can use this really helpful SWG what-if-analysis feature. It's very cool!
  8. E

    For 13,200 Gallon Plaster Pool: CircuPool RJ-30 PLUS or RJ-45 PLUS?

    Thanks for the response! I'll probably just go with the RJ-45 then. Much appreciated. I didn't think even thinking about the math you shared to determine the output over 8 hours. I'll remember this.
  9. E

    For 13,200 Gallon Plaster Pool: CircuPool RJ-30 PLUS or RJ-45 PLUS?

    Thanks for the response and advice! For the past three-ish weeks I've been daily testing and as needed and adjusting balance and FC/CC using a POOLMASTER 5in1 kit and a bottle of generic test strips. Also lots of brushing and vacuuming due to the recent resurfacing start-up. I've been able to...
  10. E

    For 13,200 Gallon Plaster Pool: CircuPool RJ-30 PLUS or RJ-45 PLUS?

    For my 13,200 gallon pool should I go with the CircuPool RJ-30 PLUS or RJ-45 PLUS? My concern is not price so much but rather if I go with the larger capacity RJ-45 PLUS will it possibly be rated to large so as to generate so much chlorine that even if I config it to it's lowest output settings...